Maintaining the T320 SIBs
Purpose
For optimum router performance, verify the condition of the SIBs.
Action
On a regular basis:
- Observe the status of the SIBs by checking the LEDs on the SIB faceplate.
- To check the status of the SIBs using the CLI, issue the show chassis environment sib command. The output is similar
to the following:
user@host> show chassis environment sibSIB 0 status: State Spare Temperature 45 degrees C / 113 degrees F Power: GROUND 0 mV 1.8 V 1794 mV 2.5 V 2446 mV 3.3 V 3291 mV 1.8 V bias 1780 mV 3.3 V bias 3284 mV 5.0 V bias 5003 mV 8.0 V bias 6910 mV SIB 1 status: State Online Temperature 45 degrees C / 113 degrees F Power: GROUND 0 mV 1.8 V 1802 mV 2.5 V 2461 mV 3.3 V 3294 mV 1.8 V bias 1782 mV 3.3 V bias 3294 mV 5.0 V bias 5013 mV 8.0 V bias 7057 mV SIB 2 status: State Online Temperature 47 degrees C / 116 degrees F Power: GROUND 0 mV 1.8 V 1794 mV 2.5 V 2461 mV 3.3 V 3301 mV 1.8 V bias 1785 mV 3.3 V bias 3296 mV 5.0 V bias 4998 mV 8.0 V bias 7050 mV
For more information about using the CLI, see the Junos OS manuals.