Technical Documentation

Maintaining the T320 SIBs

Purpose

For optimum router performance, verify the condition of the SIBs.

Action

On a regular basis:

  • Observe the status of the SIBs by checking the LEDs on the SIB faceplate.
  • To check the status of the SIBs using the CLI, issue the show chassis environment sib command. The output is similar to the following:

    user@host> show chassis environment sib
    SIB 0 status:
      State                           Spare
      Temperature                  45 degrees C / 113 degrees F
      Power:
        GROUND                      0 mV
        1.8 V                    1794 mV
        2.5 V                    2446 mV
        3.3 V                    3291 mV
        1.8 V bias               1780 mV
        3.3 V bias               3284 mV
        5.0 V bias               5003 mV
        8.0 V bias               6910 mV
    SIB 1 status:
      State                           Online
      Temperature                  45 degrees C / 113 degrees F
      Power:
        GROUND                      0 mV
        1.8 V                    1802 mV
        2.5 V                    2461 mV
        3.3 V                    3294 mV
        1.8 V bias               1782 mV
        3.3 V bias               3294 mV
        5.0 V bias               5013 mV
        8.0 V bias               7057 mV
    SIB 2 status:
      State                           Online
      Temperature                  47 degrees C / 116 degrees F
      Power:
        GROUND                      0 mV
        1.8 V                    1794 mV
        2.5 V                    2461 mV
        3.3 V                    3301 mV
        1.8 V bias               1785 mV
        3.3 V bias               3296 mV
        5.0 V bias               4998 mV
        8.0 V bias               7050 mV

For more information about using the CLI, see the Junos OS manuals.