Maintaining the T640 Routing Engines
Purpose
For optimum router performance, verify the condition of the Routing Engines.
Action
On a regular basis:
- Check the host subsystem LEDs on the craft interface. For more information about the LEDs and the display, see T640 Craft Interface Description.
- Check the LCD on the craft interface to view information about the router temperature and the status of the Routing Engines.
- Issue the show chassis routing-engine command
to check the status of the Routing Engines. The output is similar
to the following:
user@host> show chassis routing-engineRouting Engine status: Slot 0: Current state Master Election priority Master (default) Temperature 34 degrees C / 93 degrees F DRAM 2048 Mbytes CPU utilization: User 0 percent Background 0 percent Kernel 1 percent Interrupt 0 percent Idle 99 percent Start time 2002-01-22 05:21:31 UTC Uptime 10 days, 16 hours, 4 minutes, 52 seconds Load averages: 1 minute 5 minute 15 minute 0.00 0.00 0.00 Routing Engine status: Slot 1: Current state Empty
For further description of the output from the commands, see the Junos System Basics and Services Command Reference.