Technical Documentation

Maintaining the MX80 Routing Engine

Purpose

On the MX80 router, the Routing Engine is fixed inside the chassis. For optimum router performance, verify the condition of the Routing Engine.

Action

On a regular basis:

  • Check the LEDs on the front panel to view information about the status of the Routing Engine.
  • To check the status of the Routing Engine, issue the show chassis routing-engine command. The output is similar to the following:

    user@host> show chassis routing-engine
    Routing Engine status:
        Temperature                 34 degrees C / 93 degrees F
        CPU temperature             52 degrees C / 125 degrees F
        DRAM                      2048 MB
        Memory utilization          18 percent
        CPU utilization:
          User                       1 percent
          Background                 0 percent
          Kernel                     3 percent
          Interrupt                  1 percent
          Idle                      95 percent
        Model                          RE-MX80
        Start time                     2010-02-05 10:05:17 PST
        Uptime                         18 minutes, 59 seconds
        Last reboot reason             Router rebooted after a normal shutdown.
        Load averages:                 1 minute   5 minute  15 minute
                                           0.00       0.02       0.07
    