Technical Documentation

Maintaining the M10i Routing Engine

Purpose

For optimum performance, verify the condition of the Routing Engine.

Action

  • Check the LEDs on the Routing Engine. The green LED labeled ONLINE lights steadily when it is functioning normally. For more information about the LEDs, see M10i Routing Engine Description.
  • Issue the CLI show chassis routing-engine command to check the status of the Routing Engines:

    user@host> show chassis routing-engine
    Routing Engine status:
      Slot 0:
        Current state                  Master
        Election priority              Master (default)
        Temperature                 27 degrees C / 80 degrees F
        CPU temperature             27 degrees C / 80 degrees F
        DRAM                       768 MB
        Memory utilization          45 percent
        CPU utilization:
          User                       0 percent
          Background                 0 percent
          Kernel                     3 percent
          Interrupt                  0 percent
          Idle                      97 percent
        Model                          RE-5.0
        Serial ID                      1000647001
        Start time                     2009-01-28 14:11:50 PST
        Uptime                         21 hours, 51 minutes, 16 seconds
        Load averages:                 1 minute   5 minute  15 minute
                                           0.00       0.02       0.00
    
    Routing Engine status:
      Slot 1:
        Current state                  Backup
        Election priority              Backup (default)
        Temperature                 26 degrees C / 78 degrees F
        CPU temperature             27 degrees C / 80 degrees F
        DRAM                      1536 MB
        Memory utilization          23 percent
        CPU utilization:
          User                       0 percent
          Background                 0 percent
          Kernel                     0 percent
          Interrupt                  0 percent
          Idle                      99 percent
        Model                          RE-850
        Serial ID                      1000648260
        Start time                     2009-01-28 16:18:12 PST
        Uptime                         19 hours, 44 minutes, 51 seconds