Maintaining the MX240 Power Supplies
Purpose
For optimum router performance, verify the condition of the power supplies.
Action
On a regular basis:
- Check the status of the power supplies by issuing the show chassis environment pem command. The output
is similar to the following:
user@host> show chassis environment pemPEM 0 status: State Online Temperature OK DC output OK PEM 2 status: State Online Temperature OK DC output OK
- Make sure that the power and grounding cables are arranged so that they do not obstruct access to other router components.
- Routinely check the status LEDs on the power supply faceplates and the craft interface to determine if the power supplies are functioning normally.
- Check the red and yellow alarm LEDs on the craft interface.
Power supply failure or removal triggers an alarm that causes one
or both of the LEDs to light. You can display the associated error
messages by issuing the following command:
user@host> show chassis alarms - Periodically inspect the site to ensure that the grounding and power cables connected to the router are securely in place and that there is no moisture accumulating near the router.