Technical Documentation

Maintaining Port Modules on the SRX5600 Services Gateway

Purpose

For optimum services gateway performance, verify the condition of the port modules installed in Flex IOCs.

Action

On a regular basis:

  • Check the LEDs on port modules faceplates. The meaning of the LED states differs for various port modules. If the Flex IOC that houses the port modules detects a port modules failure, the Flex IOC generates an alarm message to be sent to the Routing Engine.
  • Issue the CLI show chassis fpc pic-status command. The port modules slots in an FPC are numbered from 0 through 1, left to right:

    user@host> show chassis fpc pic-status
    Slot 0   Online       SRX5k SPC
      PIC 0  Online       SPU Cp-Flow
      PIC 1  Online       SPU Flow
    Slot 3   Online       SRX5k DPC 4X 10GE
      PIC 0  Online       1x 10GE(LAN/WAN) RichQ
      PIC 1  Online       1x 10GE(LAN/WAN) RichQ
      PIC 2  Online       1x 10GE(LAN/WAN) RichQ
      PIC 3  Online       1x 10GE(LAN/WAN) RichQ
    Slot 5   Online       SRX5k FIOC
      PIC 0  Online       16x 1GE TX
      PIC 1  Online       4x 10GE XFP

    For further description of the output from the command, see the JUNOS System Basics and Services Command Reference.


Published: 2009-11-03