Technical Documentation

Maintaining MX480 PICs

Purpose

For optimum router performance, verify the condition of the PICs.

Action

On a regular basis:

  • Check the LEDs on PIC faceplates. The meaning of the LED states differs for various PICs. For more information, see the MX Series 3D Universal Edge Routers Line Card Guide. If the FPC that houses the PIC detects a PIC failure, the FPC generates an alarm message to be sent to the Routing Engine.
  • Issue the CLI show chassis fpc pic-status command. The PIC slots in an FPC are numbered from 0 through 1, left to right:

    user@host> show chassis fpc pic-status
    Slot 0   Online       DPC 40x 1GE R
      PIC 0  Online       10x 1GE(LAN)
      PIC 1  Online       10x 1GE(LAN)
      PIC 2  Online       10x 1GE(LAN)
      PIC 3  Online       10x 1GE(LAN)
    Slot 1   Online       MX FPC Type 3
      PIC 0  Online       1x OC-192 SONET
      PIC 1  Online       1x OC-192 SONET
    Slot 2   Online       MS-DPC
      PIC 0  Online       MS-DPC PIC
      PIC 1  Online       MS-DPC PIC
    Slot 3   Online       MPC Type 2 3D EQ
      PIC 0  Online       1x 10GE XFP
      PIC 1  Online       1x 10GE XFP
    Slot 4   Online       MPC 3D 16x 10GE
      PIC 0  Online       4x 10GE(LAN) SFP+
      PIC 1  Online       4x 10GE(LAN) SFP+
      PIC 2  Online       4x 10GE(LAN) SFP+
      PIC 3  Online       4x 10GE(LAN) SFP+

    For further description of the output from the command, see the Junos System Basics and Services Command Reference.


Published: 2010-08-02

Help
|
My Account
|
Log Out