Maintaining MX240 PICs
Purpose
For optimum router performance, verify the condition of the PICs and PIC cables.
Action
On a regular basis:
- Check the LEDs on PIC faceplates. The meaning of the LED states differs for various PICs. For more information, see the MX Series 3D Universal Edge Routers Line Card Guide. If the FPC that houses the PIC detects a PIC failure, the FPC generates an alarm message to be sent to the Routing Engine.
- Issue the CLI show chassis fpc pic-status command. The PIC slots in an FPC are numbered from 0 through 1, left to right:
user@host> show chassis fpc pic-statusSlot 0 Online DPC 40x 1GE R PIC 0 Online 10x 1GE(LAN) PIC 1 Online 10x 1GE(LAN) PIC 2 Online 10x 1GE(LAN) PIC 3 Online 10x 1GE(LAN) Slot 1 Online MX FPC Type 3 PIC 0 Online 1x OC-192 SONET PIC 1 Online 1x OC-192 SONETFor further description of the output from the command, see the Junos System Basics and Services Command Reference.