Technical Documentation

Maintaining MX480 MICs

Purpose

For optimum router performance, verify the condition of the MICs.

Action

On a regular basis:

  • Check the LEDs on MIC faceplates. The meaning of the LED states differs for various MICs. For more information, see the MX Series 3D Universal Edge Routers Line Card Guide. If the MPC that houses the MIC detects a MIC failure, the MPC generates an alarm message to be sent to the Routing Engine.
  • Issue the CLI show chassis fpc pic-status command. The MIC slots in an MPC are numbered PIC 0/1 and PIC 2/3, left to right:

    user@host> show chassis fpc pic-status
    Slot 0   Online       DPCE 4x 10GE R EQ
      PIC 0  Online       1x 10GE(LAN/WAN) EQ
      PIC 1  Online       1x 10GE(LAN/WAN) EQ
      PIC 2  Online       1x 10GE(LAN/WAN) EQ
      PIC 3  Online       1x 10GE(LAN/WAN) EQ
    Slot 1   Online       DPCE 40x 1GE R EQ
      PIC 0  Online       10x 1GE(LAN) EQ
      PIC 1  Online       10x 1GE(LAN) EQ
      PIC 2  Online       10x 1GE(LAN) EQ
      PIC 3  Online       10x 1GE(LAN) EQ
    Slot 2   Online       MS-DPC
      PIC 0  Online       MS-DPC PIC
      PIC 1  Online       MS-DPC PIC
    Slot 3   Online       MPC Type 2 3D EQ
      PIC 0  Online       1x 10GE XFP
      PIC 1  Online       1x 10GE XFP
    Slot 4   Online       MPC 3D 16x 10GE
      PIC 0  Online       4x 10GE(LAN) SFP+
      PIC 1  Online       4x 10GE(LAN) SFP+
      PIC 2  Online       4x 10GE(LAN) SFP+
      PIC 3  Online       4x 10GE(LAN) SFP+

    For further description of the output from the command, see the Junos System Basics and Services Command Reference.


Published: 2010-08-02