Technical Documentation

Maintaining the TX Matrix Host Subsystem

Purpose

For optimum TX Matrix performance, verify the condition of the host subsystem. The host subsystem comprises up to two Routing Engines and adjacent TX-CBs functioning together.

Action

On a regular basis:

  • Check the host subsystem LEDs (HOST 0 and HOST 1) on the craft interface. If the red HOST 0 or HOST 1 LED is lit, look at the LED display to get more information about the cause of the problem.
  • Check the LED display on the craft interface to view information about the TX Matrix router temperature and the status of the Routing Engines.
  • Check the LEDs on the TX-CB faceplate to see information about the TX-CB.
  • Check the status of the Routing Engines. Issue the show chassis routing-engine command. The output is similar to the following:

    user@host> show chassis routing-engine scc
    scc-re0:
    --------------------------------------------------------------------------
    Routing Engine status:
      Slot 0:
        Current state                  Master
        Election priority              Master (default)
        Temperature                 36 degrees C / 96 degrees F
        CPU temperature             38 degrees C / 100 degrees F
        DRAM                      2048 MB
        Memory utilization          11 percent
        CPU utilization:
          User                       0 percent
          Background                 0 percent
          Kernel                     2 percent
          Interrupt                  1 percent
          Idle                      97 percent
        Model                          RE-4.0
        Serial ID                      212058900121
        Start time                     2004-07-26 13:27:24 PDT
        Uptime                        2 hours, 34 minutes, 50 seconds
        Load averages:                 1 minute   5 minute  15 minute
                                           0.06       0.03       0.02
    Routing Engine status:
      Slot 1:           
        Current state                  Backup
        Election priority              Backup (default)
        Temperature                 36 degrees C / 96 degrees F
        CPU temperature             37 degrees C / 98 degrees F
        DRAM                      2048 MB
        Memory utilization          10 percent
        CPU utilization:
          User                       0 percent
          Background                 0 percent
          Kernel                     0 percent
          Interrupt                  1 percent
          Idle                      99 percent
        Model                          RE-4.0
        Serial ID                      211123900258
        Start time                     2004-07-26 14:16:02 PDT
        Uptime                        1 hour, 46 minutes
    
  • Check the status of the TX-CBs. Issue the show chassis environment cb command. The output is similar to the following:

    user@host> show chassis environment cb scc
    scc-re0:
    --------------------------------------------------------------------------
    CB 0 status:
      State                           Online Master
      Temperature                  34 degrees C / 93 degrees F
      Power:
        1.8 V                    1793 mV
        2.5 V                    2479 mV
        3.3 V                    3301 mV
        4.6 V                    4752 mV
        5.0 V                    5032 mV
        12.0 V                  12214 mV
        3.3 V bias               3313 mV
        8.0 V bias               7706 mV
      BUS Revision                 40
      FPGA Revision                 1
    CB 1 status:
      State                           Online Standby
      Temperature                  33 degrees C / 91 degrees F
      Power:
        1.8 V                    1785 mV
        2.5 V                    2468 mV
        3.3 V                    3293 mV
        4.6 V                    4747 mV
        5.0 V                    5025 mV
        12.0 V                  12253 mV
        3.3 V bias               3306 mV
        8.0 V bias               7721 mV
      BUS Revision                 40
      FPGA Revision                 1

For more information about using the CLI, see the Junos OS manuals.