Maintaining the M120 Host Subsystem
Purpose
For optimum router performance, verify the condition of the host subsystem. The host subsystem comprises a Routing Engine installed directly into a CB.
Action
On a regular basis:
- Check the LEDs on the craft interface to view information about the status of the Routing Engines. For more information about the LEDs and the display, see M120 Craft Interface Description.
- Check the LEDs on the CB faceplate to see information about them.
- Check the LEDs on the Routing Engine faceplate to see information about them.
- To check the status of the Routing Engines, issue the show chassis routing-engine command. The output is similar
to the following:
user@host> show chassis routing-engine routing engine statusRouting Engine status: Slot 0: Current state Master Election priority Master (default) Temperature 56 degrees C / 132 degrees F CPU temperature 63 degrees C / 145 degrees F DRAM 3584 MB Memory utilization 12 percent CPU utilization: User 0 percent Background 0 percent Kernel 6 percent Interrupt 0 percent Idle 93 percent Model RE-A-2000 Serial ID 1000642871 Start time 2006-08-29 10:06:11 PDT Uptime 57 minutes, 49 seconds Load averages: 1 minute 5 minute 15 minute 0.00 0.03 0.00 Routing Engine status: Slot 1: Current state Backup Election priority Backup (default) Temperature 45 degrees C / 113 degrees F CPU temperature 52 degrees C / 125 degrees F DRAM 3584 MB Memory utilization 10 percent CPU utilization: User 0 percent Background 0 percent Kernel 0 percent Interrupt 0 percent Idle 100 percent Model RE-A-2000 Serial ID 1000636825 Start time 2006-08-29 09:34:59 PDT Uptime 1 hour, 28 minutes, 51 seconds - To check the status of the CBs, issue the show chassis
environment cb command. The output is similar to the following:
user@host> show chassis environment cbCB 0 status: State Online Master Temperature 67 degrees C / 152 degrees F Power 1.2 V 1218 mV 1.5 V 1498 mV 2.5 V 2520 mV 3.3 V 3332 mV 5.0 V 5066 mV 3.3 V bias 3296 mV Bus Revision 15 FPGA Revision 20 CB 1 status: State Online Standby Temperature 66 degrees C / 150 degrees F Power 1.2 V 1214 mV 1.5 V 1501 mV 2.5 V 2510 mV 3.3 V 3306 mV 5.0 V 5111 mV 3.3 V bias 3296 mV Bus Revision 15 FPGA Revision 20
For more information about using the CLI, see the Junos OS documentation.