Maintaining MX240 DPCs
Purpose
For optimum router performance, verify the condition of the Dense Port Concentrators (DPCs). The router can have up to three DPCs mounted horizontally in the DPC card cage at the front of the chassis.
Action
On a regular basis:
- Check the LEDs on the craft interface directly above each DPC slot. The green LED labeled OK lights steadily when a DPC is functioning normally.
- Check the OK/FAIL LED on the DPC. If the DPC detects a failure, the DPC sends an alarm message to the Routing Engine.
- Issue the CLI show chassis fpc command
to check the status of installed DPCs. As shown in the sample
output, the value Online in the column labeled State indicates that the DPC is functioning normally:
user@host> show chassis fpcTemp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 0 Online 41 9 0 1024 15 57 1 Online 43 5 0 1024 16 57 2 Online 43 11 0 1024 16 57
For more detailed output, add the detail option. The following example does not specify a slot number, which is optional:
user@host> show chassis fpc detailSlot 0 information: State Online Temperature 33 degrees C / 91 degrees F Total CPU DRAM 1024 MB Total RLDRAM 256 MB Total DDR DRAM 4096 MB Start time: 2007-12-06 11:33:00 PST Uptime: 4 hours, 34 minutes, 49 seconds Slot 1 information: State Online Temperature 33 degrees C / 91 degrees F Total CPU DRAM 1024 MB Total RLDRAM 256 MB Total DDR DRAM 4096 MB Start time: 2007-12-06 11:33:01 PST Uptime: 4 hours, 34 minutes, 48 seconds Slot 2 information: State Online Temperature 33 degrees C / 91 degrees F Total CPU DRAM 1024 MB Total RLDRAM 256 MB Total DDR DRAM 4096 MB Start time: 2007-12-06 11:33:05 PST Uptime: 4 hours, 34 minutes, 44 seconds
- Issue the CLI show chassis fpc pic-status command. The DPC slots are numbered 1/0, 1, and 2, bottom to top:
user@host> show chassis fpc pic-statusSlot 0 Online DPCE 4x 10GE R PIC 0 Online 1x 10GE(LAN/WAN) PIC 1 Online 1x 10GE(LAN/WAN) PIC 2 Online 1x 10GE(LAN/WAN) PIC 3 Online 1x 10GE(LAN/WAN) Slot 1 Online DPCE 40x 1GE R PIC 0 Online 10x 1GE(LAN) PIC 1 Online 10x 1GE(LAN) PIC 2 Online 10x 1GE(LAN) PIC 3 Online 10x 1GE(LAN) Slot 2 Online DPCE 40x 1GE R PIC 0 Online 10x 1GE(LAN) PIC 1 Online 10x 1GE(LAN) PIC 2 Online 10x 1GE(LAN) PIC 3 Online 10x 1GE(LAN)
For further description of the output from the command, see the Junos System Basics and Services Command Reference.