Technical Documentation

Identifying EX4500 Switch Models

Purpose

Identify the model number of your EX4500 switch.

Action

Check the value of the Routing Engine (FRU Model Number) field in the output of the show chassis hardware extensive CLI command.

user@switch>show chassis hardware extensive

....
Routing Engine 0 REV 00D  750-026816   DE0210022651      EX4500-40F
 Jedec Code:   0x7fb0            EEPROM Version:    0x02
 P/N:          750-026816        S/N:               DE0210022651
 Assembly ID:  0x095a            Assembly Version:  05.00
 Date:         01-21-2010        Assembly Flags:    0x00
 Version:      REV 00D           CLEI Code:         COMUX00CRA
 ID: EX4500-40F                  FRU Model Number:  EX4500-40F-FB
....

The model number of your switch is one of the following:

  • EX4500-40F-FB
  • EX4500-40F-BF
  • EX4500-40F-FB-C
  • EX4500-40F-BF-C

Meaning

  • The FB and BF in the model number indicate the direction of airflow of the chassis:
    • FB—Front-to-back airflow
    • BF—Back-to-front airflow
  • The C in the model number indicates the Converged Enhanced Ethernet (CEE) status of switch:
    • C—CEE capable
    • None—Not CEE capable

Note: The CEE-capable EX4500 switches have a Virtual Chassis label on the front panel. See Front Panel of an EX4500 Switch.

Related Topics


Published: 2010-07-15

Help
|
My Account
|