Troubleshooting SRX5800 Services Gateway Port Modules

Problem

The port modules are not functioning normally.

Solution

  • Check the status of each port on a port module by looking at the LED located on the port module faceplate.
  • Check the status of a port module by issuing the show chassis fpc pic-status CLI command. The port module slots in the Flex IOC are numbered from 0 through 1:

    user@host> show chassis fpc pic-status
    Slot 0   Online       SRX5k SPC
      PIC 0  Online       SPU Cp-Flow
      PIC 1  Online       SPU Flow
    Slot 3   Online       SRX5k DPC 4X 10GE
      PIC 0  Online       1x 10GE(LAN/WAN) RichQ
      PIC 1  Online       1x 10GE(LAN/WAN) RichQ
      PIC 2  Online       1x 10GE(LAN/WAN) RichQ
      PIC 3  Online       1x 10GE(LAN/WAN) RichQ
    Slot 5   Online       SRX5k FIOC
      PIC 0  Online       16x 1GE TX
      PIC 1  Online       4x 10GE XFP

    For further description of the output from the command, see the JUNOS System Basics and Services Command Reference.