Troubleshooting SRX5800 Services Gateway Port Modules
Problem
The port modules are not functioning normally.
Solution
- Check the status of each port on a port module by looking at the LED located on the port module faceplate.
- Check the status of a port module by issuing the show
chassis fpc pic-status CLI command. The port module slots in
the Flex IOC are numbered from 0 through 1:
user@host> show chassis fpc pic-statusSlot 0 Online SRX5k SPC PIC 0 Online SPU Cp-Flow PIC 1 Online SPU Flow Slot 3 Online SRX5k DPC 4X 10GE PIC 0 Online 1x 10GE(LAN/WAN) RichQ PIC 1 Online 1x 10GE(LAN/WAN) RichQ PIC 2 Online 1x 10GE(LAN/WAN) RichQ PIC 3 Online 1x 10GE(LAN/WAN) RichQ Slot 5 Online SRX5k FIOC PIC 0 Online 16x 1GE TX PIC 1 Online 4x 10GE XFP
For further description of the output from the command, see the JUNOS System Basics and Services Command Reference.