Troubleshooting M120 PICs

Problem

The PICs are not functioning normally.

Solution

To troubleshoot the PICs:

  • Check the status of each port on a PIC by looking at the LED located on the PIC faceplate. For information about the meaning of LED states on different PICs, see the M120 PIC Guide.
  • To check the status of a PIC, issue the following CLI command. The PIC slots in the FPC are numbered from 0 through 3, top to bottom:

    user@host> show chassis fpc pic-status
    Slot 2   Online       M120 FPC Type 1 
      PIC 2  Present      1x G/E, 1000 BASE-SX- Not Supported
      PIC 3  Online       1x Tunnel
    Slot 3   Online       M120 FPC Type 2 
      PIC 0  Online       4x OC-3 SONET, SMIR
      PIC 1  Present      2x G/E, 1000 BASE-SX- Not Supported
      PIC 2  Online       4x G/E SFP, 1000 BASE
      PIC 3  Present      1x OC-48 SONET, SMSR- Not Supported
    Slot 4   Online       M120 FPC Type 3 
    Slot 5   Online       M120 FPC Type 1 
      PIC 0  Online       1x G/E SFP, 1000 BASE
      PIC 2  Online       4x CHDS3 IQ

    Note: If a PIC does not come online as expected, check the assigned FEB, as described in Troubleshooting M120 FEBs.

    For further description of the output from the command, see the Junos System Basics and Services Command Reference.