Troubleshooting M120 PICs
Problem
The PICs are not functioning normally.
Solution
To troubleshoot the PICs:
- Check the status of each port on a PIC by looking at the LED located on the PIC faceplate. For information about the meaning of LED states on different PICs, see the M120 PIC Guide.
- To check the status of a PIC, issue the following CLI
command. The PIC slots in the FPC are numbered from 0 through 3, top to bottom:
user@host> show chassis fpc pic-statusSlot 2 Online M120 FPC Type 1 PIC 2 Present 1x G/E, 1000 BASE-SX- Not Supported PIC 3 Online 1x Tunnel Slot 3 Online M120 FPC Type 2 PIC 0 Online 4x OC-3 SONET, SMIR PIC 1 Present 2x G/E, 1000 BASE-SX- Not Supported PIC 2 Online 4x G/E SFP, 1000 BASE PIC 3 Present 1x OC-48 SONET, SMSR- Not Supported Slot 4 Online M120 FPC Type 3 Slot 5 Online M120 FPC Type 1 PIC 0 Online 1x G/E SFP, 1000 BASE PIC 2 Online 4x CHDS3 IQ

Note: If a PIC does not come online as expected, check the assigned FEB, as described in Troubleshooting M120 FEBs.
For further description of the output from the command, see the Junos System Basics and Services Command Reference.