Troubleshooting the MX80 MICs
Problem
The MICs are not functioning normally.
Solution
- Check the status of each port on a MIC by looking at the LED located on the MIC faceplate. For information about the meaning of LED states on different MICs, see the MX Series 3D Universal Edge Routers Line Card Guide.
- Check the status of a MIC by issuing the show chassis
fpc pic-status CLI command. The MIC slots in the modular MX80
router are labeled 1/MIC 0 and 1/MIC 1. The fixed
MIC is labeled 0/MIC 0.
user@host> show chassis fpc pic-statusSlot 0 Online PIC 0 Online 4x 10GE XFP PIC 2 Online 1x 10GE XFP PIC 3 Online 1x 10GE XFP Slot 1 Online PIC 0 Online 1x 10GE XFP PIC 1 Online 1x 10GE XFP PIC 2 Online 1x 10GE XFP PIC 3 Online 1x 10GE XFP
For further description of the output from the command, see the Junos System Basics and Services Command Reference.