Technical Documentation

Troubleshooting the MX80 MICs

Problem

The MICs are not functioning normally.

Solution

  • Check the status of each port on a MIC by looking at the LED located on the MIC faceplate. For information about the meaning of LED states on different MICs, see the MX Series 3D Universal Edge Routers Line Card Guide.
  • Check the status of a MIC by issuing the show chassis fpc pic-status CLI command. The MIC slots in the modular MX80 router are labeled 1/MIC 0 and 1/MIC 1. The fixed MIC is labeled 0/MIC 0.

    user@host> show chassis fpc pic-status
    Slot 0   Online      
      PIC 0  Online       4x 10GE XFP
      PIC 2  Online       1x 10GE XFP
      PIC 3  Online       1x 10GE XFP
    Slot 1   Online      
      PIC 0  Online       1x 10GE XFP
      PIC 1  Online       1x 10GE XFP
      PIC 2  Online       1x 10GE XFP
      PIC 3  Online       1x 10GE XFP

    For further description of the output from the command, see the Junos System Basics and Services Command Reference.


Published: 2010-08-13

Help
|
My Account
|
Log Out