Troubleshooting the MX240 MICs
Problem
The MICs are not functioning normally.
Solution
- Check the status of each port on a MIC by looking at the LED located on the MIC faceplate. For information about the meaning of LED states on different MICs, see the MX Series 3D Universal Edge Routers Line Card Guide.
- Check the status of a MIC by issuing the show chassis
fpc pic-status CLI command. The MIC slots in the MPC are labeled PIC 0/1 and PIC 2/3, left to right:
user@host> show chassis fpc pic-statusSlot 0 Online MPC Type 2 3D EQ PIC 0 Online 1x 10GE XFP PIC 1 Online 1x 10GE XFP Slot 1 Online MPC 3D 16x 10GE PIC 0 Online 4x 10GE(LAN) SFP+ PIC 1 Online 4x 10GE(LAN) SFP+ PIC 2 Online 4x 10GE(LAN) SFP+ PIC 3 Online 4x 10GE(LAN) SFP+ Slot 2 Online MS-DPC PIC 0 Online MS-DPC PIC PIC 1 Online MS-DPC PIC
For further description of the output from the command, see the Junos System Basics and Services Command Reference.