Technical Documentation

Troubleshooting the MX240 MICs

Problem

The MICs are not functioning normally.

Solution

  • Check the status of each port on a MIC by looking at the LED located on the MIC faceplate. For information about the meaning of LED states on different MICs, see the MX Series 3D Universal Edge Routers Line Card Guide.
  • Check the status of a MIC by issuing the show chassis fpc pic-status CLI command. The MIC slots in the MPC are labeled PIC 0/1 and PIC 2/3, left to right:

    user@host> show chassis fpc pic-status
    Slot 0   Online       MPC Type 2 3D EQ
      PIC 0  Online       1x 10GE XFP
      PIC 1  Online       1x 10GE XFP
    Slot 1   Online       MPC 3D 16x 10GE
      PIC 0  Online       4x 10GE(LAN) SFP+
      PIC 1  Online       4x 10GE(LAN) SFP+
      PIC 2  Online       4x 10GE(LAN) SFP+
      PIC 3  Online       4x 10GE(LAN) SFP+
    Slot 2   Online       MS-DPC
      PIC 0  Online       MS-DPC PIC
      PIC 1  Online       MS-DPC PIC

    For further description of the output from the command, see the Junos System Basics and Services Command Reference.