Troubleshooting the T320 FPCs
Problem
During normal operation the STATUS LED lights red steadily.
Solution
- If the red FAIL LED above the FPC is on, look at the display on the craft interface to check the status of the FPC and the PICs that are plugged into it.
- Make sure the FPC is properly seated in the midplane. Check that each ejector handle has been turned clockwise and is tight. Use a screwdriver to check that the screws inside the ejector handles are tight.
- To check the status of an FPC, use the following CLI command:
user@host> show chassis fpcTo display more detailed information, use the following option:
user@host> show chassis fpc detail