Troubleshooting the T1600 FPCs
Problem
The following LEDs indicate a problem with an FPC:
- The red FAIL LED above the FPC is on.
During normal operation:
- The green STATUS LED above the FPC on the craft interface lights steadily when the FPC is online and functioning normally.
- The green STATUS LED blinks during startup.
Solution
To troubleshoot an FPC:
- Look at the display on the craft interface to check the status of the FPC and the PICs that are plugged into it.
- Verify that the FPC is properly seated in the midplane. Check that each ejector handle has been turned clockwise and is tight. Use a screwdriver to check that the screws inside the ejector handles are tight.
- Check the status of an FPC using the following
CLI command:
user@host> show chassis fpc - Use the following option to display more detailed
information:
user@host> show chassis fpc detail