Monitoring the SRX240 Services Gateway Chassis Using the CLI
You can monitor alarms to troubleshoot hardware problems on a services gateway. The chassis properties include the status of active chassis alarms on the device, environment measurements, and the status of Mini-PIMs on the device.
To view these chassis properties, select Monitor>Chassis in the J-Web interface, or enter the following CLI show commands:
- show chassis hardware
- show chassis environment
- show chassis fpc
- show chassis alarms
Examples:
The following examples provide the sample output of commands:
- show chassis hardware command
(on SRX240 Services Gateway Low Memory model)
user@host > show chassis hardware
Item Version Part number Serial number Description Chassis AF1111AA7997 SRX240b Routing Engine REV 01 750-021792 PW7997 RE-SRX240-LM FPC 0 FPC PIC 0 16x GE Base PIC FPC 1 REV 01 750-023367 PS0699 FPC PIC 0 1x T1E1 mPIM FPC 3 REV 02 750-025085 AAAG5759 FPC PIC 0 1x Serial mPIM FPC 4 REV 02 750-025085 AAAG5812 FPC PIC 0 1x Serial mPIM Power Supply 0
The output sample for the SRX240 Services Gateway with Integrated Convergence Services.
Item Version Part number Serial number Description Chassis SRX240h-p-m Routing Engine REV 00 750-024366 AAAN7131 RE-SRX240H-P-M FPC 0 FPC PIC 0 16xGE, 2xFXS, 2xFXO ANNEX REV 01 711–028413 AAAR3414 SRX240 VOICE Mezzanine FPC 3 FPC PIC 0 4xFXO mPIM Power Supply 0
- show chassis environment command
Class Item Status Measurement Temp Routing Engine OK 36 degrees C / 96 degrees F Routing Engine CPU Absent Fans SRX240 Chassis fan 0 OK Spinning at high speed SRX240 Chassis fan 1 OK Spinning at high speed Power Power Supply 0 OK - show chassis fpc command
user@host > show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 0 Online -------------------- CPU less FPC -------------------- 1 Online -------------------- CPU less FPC -------------------- 2 Online -------------------- CPU less FPC -------------------- 3 Online -------------------- CPU less FPC -------------------- 4 Online -------------------- CPU less FPC -------------------- - show chassis alarms command
user@host > show chassis alarms
1 alarms currently active Alarm time Class Description 2010-01-04 17:11:06 UTC Minor Host 0 Boot firmware requires upgrade
For more information, see the JUNOS Software Administration Guide.