Monitoring the SRX210 Services Gateway Chassis Using the CLI
You can monitor alarms to troubleshoot hardware problems on a services gateway. The chassis properties include the status of active chassis alarms on the device, environment measurements, and the status of Mini-PIMs on the device.
To view these chassis properties, select Monitor in the J-Web interface, or enter the following CLI show commands:
- show chassis hardware
- show chassis hardware detail
- show chassis environment
- show chassis fpc
- show chassis alarms
Examples:
The following examples provide the sample output of commands:
show chassis hardware
- For the SRX210 Services Gateway
user@host > show chassis hardware
Item Version Part number Serial number Description Chassis SRX210b Routing Engine REV X0 750-021778 000000PS2627 RE-SRX210-LOWMEM FPC 0 FPC PIC 0 2x GE, 6x FE, 1x 3G Power Supply 0
- For the SRX210 Services Gateway with Integrated Convergence Services
user@host > show chassis hardware
Item Version Part number Serial number Description Chassis Routing Engine REV 01 750-021778 VG8859 RE-SRX210-VOICE FPC 0 FPC PIC 0 2x GE, 6x FE, 1x 3G, 2xFXS, 1xFXO Power Supply 0
show chassis hardware detail
user@host > show chassis hardware detail
Hardware inventory: Item Version Part number Serial number Description Chassis SRX210b Routing Engine REV X0 750-021778 000000PS2631 RE-SRX210-LOWMEM da0 999 MB ST72682 Nand Flash usb0 (addr 1) DWC OTG root hub 0 vendor 0x0000 uhub0 usb0 (addr 2) product 0x6254 25172 vendor 0x058f uhub1 usb0 (addr 3) ST72682 High Speed Mode 64218 STMicroelectronics umass0 FPC 0 FPC PIC 0 2x GE, 6x FE, 1x 3G Power Supply 0
![]() | Note: The values given in the usb0 rows provide information for USB level debugging. This information is about USB hub topology. |
show chassis environment
user@host > show chassis environment
Class Item Status Measurement Temp Routing Engine OK 33 degrees C / 91 degrees F Fans SRX210 Chassis fan OK Spinning at intermediate-speed Power Power Supply 0 OK
show chassis fpc
user@host > show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 0 Online -------------------- CPU less FPC -------------------- 1 Online -------------------- CPU less FPC --------------------
show chassis alarms
user@host > show chassis alarms
Alarm time Class Description 2009-05-11 10:47:47 UTC Major SRX210 Chassis Fan Failure