Technical Documentation

Maintaining the Routing Engine on the SRX3600 Services Gateway

The host subsystem comprises a Routing Engine installed directly into the midplane. To maintain the host subsystem components, follow these guidelines:

  • Check the LEDs on the SFB faceplate.
  • Check the LEDs on the Routing Engine faceplate.
  • To check the status of the Routing Engine, issue the show chassis routing-engine command. The output is similar to the following:

    user@host> show chassis routing-engine
    Routing Engine status:
      Slot 0:
        Current state                  Master
        Election priority              Master (default)
        DRAM                      1023 MB
        Memory utilization          34 percent
        CPU utilization:
          User                       0 percent
          Background                 0 percent
          Kernel                     3 percent
          Interrupt                  0 percent
          Idle                      96 percent
        Model                          RE-PPC-1200-A
        Start time                     2010-04-05 14:01:33 PDT
        Uptime                         47 minutes, 48 seconds
        Last reboot reason             Router rebooted after a normal shutdown.
        Load averages:                 1 minute   5 minute  15 minute
                                           0.04       0.04       0.05
  • To check the status of the SFB, issue the show chassis environment cb command. The output is similar to the following:

    user@host> show chassis environment cb
    CB 0 status:
      State                      Online Master
      Temperature                37 degrees C / 98 degrees F
      Power 1
        1.0 V                      982 mV
        1.1 V                     1057 mV
        1.2 V                     1169 mV
        1.25 V                    1214 mV
        1.5 V                     1450 mV
        1.8 V                     1753 mV
        2.5 V                     2449 mV
        3.3 V                     3248 mV
        3.3 V bias                3296 mV
        5.0 V                     4975 mV
        12.0 V                   11640 mV
      Bus Revision               108
      FPGA Revision              0
    

For more information about using the CLI, see the JUNOS Software manuals.


Published: 2010-04-20