Technical Documentation

Reinstalling the M320 CBs

To reinstall CBs (see Figure 1):

  1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
  2. Carefully align the sides of the CB with the guides inside the chassis.
  3. Slide the CB into the chassis, carefully ensuring that it is correctly aligned.
  4. Grasp both ejector handles and press them inward to seat the CB.
  5. Tighten the captive screws on the ejector handles, using a Phillips (+) screwdriver, number 2.
  6. Repeat the procedure to reinstall the remaining CB.

Figure 1: Reinstalling a CB

Image g003464.gif