Installing the SRX210 Services Gateway in a Rack
You can front-mount the SRX210 Services Gateway in a rack. Many types of racks are acceptable, including four-post (telco) racks, enclosed cabinets, and open-frame racks. For more information about the type of rack or cabinet the SRX210 Services Gateway can be installed into, see SRX210 Services Gateway Rack Requirements.
![]() | Note: The rack-mounting kit is not shipped with the device and must be ordered separately. |
![]() |
|
To install the device in a rack:
- Position a mounting bracket on each side of the
chassis as shown in Figure 1.
Figure 1: Installation of SRX210 Services Gateway in a Rack — Positioning Mounting Brackets

Table 1 lists the parts used for installing the SRX210 Services Gateway on the rack. The numbers in Figure 1 correspond to the numbers in Table 1.
Table 1: SRX210 Services Gateway Rack Installation Parts
S.No
Part
1
Mounting brackets
2
Screws (mounting bracket)
3
Power supply adapter tray
4
Adapter stopper bracket
- Use a number-1 Phillips screwdriver to install
the screws that secure the mounting brackets and power supply adapter
tray to the chassis as shown in Figure 2.
Figure 2: SRX210 Services Gateway Rack Installation — Securing Mounting Brackets and Power Supply Adapter Tray

- Place
the power supply adapter in the tray as shown in Figure 3.
Figure 3: SRX210 Services Gateway Rack Installation — Positioning Power Supply Adapter Tray

- Have one person grasp the sides of the device, lift it, and position it in the rack.
- Align the bottom hole in each mounting bracket
with a hole in each rack rail as shown in Figure 4, making sure
the chassis is level.
Figure 4: SRX210 Services Gateway Rack Installation — Hanging the Services Gateway in a Rack

- Have a second person install a mounting screw into each of the two aligned holes. Use a number-3 Phillips screwdriver to tighten the screws.
- Install the second screw in each mounting bracket.
- Verify that the mounting screws on one side of the rack are aligned with the mounting screws on the opposite side and that the device is level.
Related Topics
- SRX210 Services Gateway General Safety Guidelines and Warnings
- Required Tools and Parts for Installing and Maintaining the SRX210 Services Gateway
- Preparing the SRX210 Services Gateway for Rack-Mount Installation
- Adjusting the Power Supply Adapter Tray for the SRX210 Services Gateway for Rack-Mount Installation
- Installing the SRX210 Services Gateway on a Desk
- Installing the SRX210 Services Gateway on a Wall