Technical Documentation

Removing the SRX5600 Services Gateway Routing Engine

Caution: Before you replace a Routing Engine, you must take the host subsystem offline.

To remove the Routing Engine (see Figure 1):

  1. Take the host subsystem offline as described in Taking the SRX5600 Services Gateway Host Subsystem Offline.
  2. Place an electrostatic bag or antistatic mat on a flat, stable surface.
  3. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
  4. Flip the ejector handles outward to unseat the Routing Engine.
  5. Grasp the Routing Engine by the ejector handles and slide it about halfway out of the chassis.
  6. Place one hand underneath the Routing Engine to support it and slide it completely out of the chassis.
  7. Place the Routing Engine on the antistatic mat.

Figure 1: Removing a Routing Engine

Image g030250.gif


Published: 2009-11-03