Removing a T640 PIC
PICs are hot-insertable and hot-removable. When you remove a PIC, the router continues to function, although the PIC interfaces being removed no longer function.
The PICs are located in the FPCs installed in the front of the router. A PIC weighs less than 2 lb (0.9 kg).
To remove a PIC (see Figure 1):
- Place an electrostatic bag or antistatic mat on a flat, stable surface to receive the PIC. If the PIC connects to fiber-optic cable, have ready a rubber safety cap for each transceiver and cable.
- Attach an electrostatic discharge ESD grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
- Use one of the following methods to take the PIC
offline:
- Press and hold the online/offline button until the PIC
LED goes out (about 5 seconds).
For a PIC installed in a Type 1 FPC, use a tool—such as a flat-blade screwdriver—to press the button slightly beneath the faceplate of the PIC. For a PIC installed in a Type 2 FPC or Type 3 FPC, use a narrow-ended tool that fits inside the opening that leads to the button.
- Issue the following CLI command:
user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot offlineFor more information about the command, see the Junos System Basics and Services Command Reference.
- Press and hold the online/offline button until the PIC
LED goes out (about 5 seconds).
- Label the cables connected to the PIC so that you can later reconnect each cable to the correct PIC.
- Disconnect the cables from the PIC. If the PIC
uses fiber-optic cable, immediately cover each transceiver and the
end of each cable with a rubber safety cap.

Warning: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.

Caution: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
- Arrange the cable in the cable management system
to prevent it from dislodging or developing stress points. Secure
the cable so that it is not supporting its own weight as it hangs
to the floor. Place excess cable out of the way in a neatly coiled
loop in the cable management system. Placing fasteners on the loop
helps to maintain its shape.

Caution: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
- Unseat the PIC:
- Type 1 or Type 2 PIC—Loosen the captive screws at the top and bottom of the PIC faceplate.
- Type 3 PIC—Loosen the captive screw at the bottom of the PIC faceplate, then twist the ejector handle at the top of the faceplate and counterclockwise to unseat the PIC.
- Type 4 PIC—Twist the ejector handle at the bottom of the PIC faceplate, then twist the ejector handle at the top of the faceplate and counterclockwise to unseat the PIC.
- Slide the PIC out of the FPC card carrier, and place it in the electrostatic bag or on the antistatic mat.
- If you are not reinstalling a PIC into the emptied PIC slot within a short time, install a blank PIC panel over the slot to maintain proper airflow in the FPC card cage.
Figure 1: Removing a PIC