Technical Documentation

Installing an M7i PIC

Warning: Do not look directly into transceivers or into the ends of fiber-optic cables connected to a transceiver. Fiber-optic transceivers emit laser light that can damage your eyes.

Caution: When handling fiber-optic transceivers and fiber-optic cable, observe the following precautions:

  • Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
  • Do not bend fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
  • Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.

To install a PIC (see Figure 1):

  1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis. Verify that the router is attached to a proper earth ground.
  2. If the PIC uses fiber-optic cable, verify that there is a rubber safety cap over each transceiver on the faceplate. Install a cap if necessary.
  3. Pull the ejector lever away from the PIC faceplate and hold it while you insert the PIC.
  4. Align the rear of the PIC with the guides located at the bottom corners of the PIC slot.
  5. Slide the PIC into the card cage until about 0.5 in. (1 cm) of the PIC remains outside the slot and you feel some resistance. Release the ejector lever.

    Caution: Be careful to insert the PIC straight into the chassis to avoid damaging the components on the bottom of the PIC.

  6. Continue pushing the PIC until it contacts the midplane and you hear a click. The ejector lever engages and closes automatically.
  7. If the PIC uses fiber-optic cable, remove the rubber safety cap from each transceiver.
  8. Insert the appropriate cable into the cable connector ports on the PIC.
  9. Arrange the cable to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop. Placing fasteners on the loop helps to maintain its shape.
  10. Press and hold the PIC offline button on the FIC until the normal function indicator LED lights, which usually takes about 5 seconds. The normal function indicator LED is usually green; for more information, see the M7i Multiservice Edge Router PIC Guide.

You can verify correct PIC functioning by issuing the show chassis fpc pic-status command, described in Maintaining the M7i FIC and FIC Cables and PICs and PIC Cables.

Figure 1: Installing a PIC

Image g003228.gif


Published: 2010-08-14