Installing an MX80 MIC

To install a MIC (see Figure 2):

  1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
  2. If the MIC uses fiber-optic cable, verify that a rubber safety cap is over each transceiver on the faceplate. Install a cap if necessary.
  3. If you have used a dual-wide MIC and are now replacing it with two “single” MICs, install the septum (see Figure 1):
    1. Align the bottom of the septum with the groves in the center of the two MIC slots.
    2. Slide the septum towards the rear of the chassis until it is seated firmly in place.

    Figure 1: Installing the Septum

    Image g005034.gif

  4. Pull the ejector lever above the MIC slot away from the router.
  5. Align the rear of the MIC with the guides located at the corners of the MIC slot.
  6. Slide the MIC into the MIC slot until it is firmly seated in the chassis.

    Caution: Slide the MIC straight into the slot to avoid damaging the components on the MIC.

  7. Verify that the ejector lever is engaged by pushing it toward the router.
  8. If the MIC uses fiber-optic cable, remove the rubber safety cap from each transceiver and the end of each cable.

    Warning: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.

    Caution: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.

  9. Insert the appropriate cables into the cable connectors on the MIC.
  10. Arrange each cable to prevent the cable from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop.

    Caution: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.

    Caution: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.

  11. Use one of the following methods to bring the MIC online:
    • Press the MIC offline/online button until the MIC OK/FAIL LED lights green.
    • Issue the following CLI command:

      user@host> request chassis mic fpc-slot slot-number mic-slot slot-number online

    The normal functioning status LED confirms that the MIC is online. You can also verify correct MIC functioning by issuing the show chassis fpc pic-status command described in Maintaining the MX80 MICs.

Figure 2: Installing a MIC

Image g005029.gif


Published: 2010-08-13