Installing an SRX5800 Services Gateway Flex IOC
![]() |
Note: Your services gateway must be running JUNOS version 9.5R1 or later in order to recognize Flex IOCs and port modules. |
To install a Flex IOC (see Figure 1):
- Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
- Place the Flex IOC on an antistatic mat or remove it from its electrostatic bag.
- Identify the slot on the services gateway where you will install the Flex IOC.
- If you have not already done so, remove the blank panel from the slot where you are installing the Flex IOC.
- Orient the Flex IOC so that the faceplate faces you, the text on the card is right-side up, and the EMI strip is on the right-hand side.
- Lift the Flex IOC into place and carefully align first the bottom and then the top of the card with the guides inside the card cage.
- Slide the Flex IOC all the way into the card cage
until you feel resistance.
Figure 1: Installing a Flex IOC

- Grasp both ejector handles and rotate them clockwise simultaneously until the Flex IOC is fully seated.
- Use one of the following methods to bring the Flex
IOC online:
- Press and hold the corresponding online button on the craft interface until the green OK LED next to the button lights steadily, in about 5 seconds.
- Issue the following CLI command:
user@host>request chassis fpc slot slot-number onlineFor more information about the command, see the JUNOS System Basics and Services Command Reference.

Caution: After the OK LED turns green, wait at least 30 seconds before removing the card again, removing a card from a different slot, or inserting a card in a different slot.