Removing an M7i FIC or PIC Cable
![]() | Warning: Do not look directly into transceivers or into the ends of fiber-optic cables connected to a transceiver. Fiber-optic transceivers emit laser light that can damage your eyes. |
![]() | When handling fiber-optic transceivers and fiber-optic cable, observe the following precautions:
|
To remove a FIC or PIC cable:
- If the interface connects to fiber-optic cable, have ready a rubber safety cap for each cable you are removing.
- If removing all cables connected to the interface, press and hold the PIC offline button on the FIC until its failure indicator LED lights, which usually takes about 5 seconds. The failure LED is usually red; for more information, see the M7i Multiservice Edge Router PIC Guide.
- Unplug the cable from the cable connector port. If the interface uses fiber-optic cable, immediately cover each transceiver and the end of each cable with a rubber safety cap.
- Arrange the cable to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop. Placing fasteners on the loop helps to maintain its shape.