Basic Configuration of the G.SHDSL Mini-Physical Interface Module
To enable the G.SHDSL Mini-Physical Interface Module (Mini-PIM) installed on the SRX Series Services Gateway, you must configure its properties. You can perform the same configuration tasks using J-Web or the CLI. In addition, you can configure a wider variety of options that are encountered less frequently.
To perform basic perform basic configuration of the G.SHDSL Mini-PIM and configure network interfaces for the services gateway with the CLI:
- Verify that the G.SHDSL Mini-PIM is installed on the services
gateway:
show chassis hardware
- Verify the status of the interface:
show interfaces terse
- Assign the port an IP address:
set interface at-1/0/0 unit 0 family inet address interface address/destination prefix
- Add or select a security zone, for example, Zone1:
set security zones security-zone zone1 interfaces at-1/0/0.0 host-inbound-traffic system-services all
- Add or select a security zones for host inbound traffic
protocol options:
set security zones security-zone zone1 interfaces at-1/0/0.0 host-inbound-traffic protocols all
- Set security policies:
set security policies default-policy permit-all