Upgrading or Downgrading an M10i CFEB or CFEB-E
To upgrade by replacing a CFEB with a CFEB-E or downgrade by replacing a CFEB-E with a CFEB requires a system reboot after swapping the CFEB devices.
To upgrade from a CFEB to a CFEB-E or to downgrade from a CFEB-E to a CFEB:
- Remove the CFEB or CFEB-E as described in Removing an M10i CFEB or CFEB-E.
- Install the upgrade CFEB-E or downgrade CFEB as described in Installing an M10i CFEB or CFEB-E.
- Reboot the router:
- If the router has only one routing engine, issue the CLI
command
user@host> request system reboot - If the router has two routing engines (a primary routing
engine and a backup routing engine), from the primary routing engine
issue the following two CLI commands in immediate succession to force
the router to reboot:
user@host> request system reboot other-routing-engineuser@host> request system reboot
- If the router has only one routing engine, issue the CLI
command
After the reboot, the router recognizes the new CFEB or CFEB-E.