TX Matrix Router Environmental Specifications
Table 1 specifies the environmental specifications required for normal TX Matrix router operation. In addition, the site should be as dust-free as possible. Dust can clog air intake vents, reducing cooling system efficiency. Check the vents frequently, cleaning them as necessary.
Table 1: TX Matrix Router Environmental Specifications
Description | Value |
|---|---|
Altitude | No performance degradation to 10,000 ft (3048 m) |
Relative humidity | Normal operation ensured in relative humidity range of 5% to 90%, noncondensing |
Temperature | Normal operation ensured in temperature range of 32°F (0°C) to 104°F (40°C) Nonoperating storage temperature in shipping crate: –40°F (–40°C) to 158°F (70°C) |
Seismic | Tested to meet Telcordia Technologies Zone 4 earthquake requirements |
Maximum thermal output | 15,559 BTU/hour (4560 W) |
![]() | Note: Install the TX Matrix router only in restricted areas, such as dedicated equipment rooms and equipment closets, in accordance with Articles 110-16, 110-17, and 110-18 of the National Electrical Code, ANSI/NFPA 70. |

