Technical Documentation

EX8208 Switch Configurations

Table 1 lists the seven sample hardware configurations for an EX8208 switch—base (AC), redundant (AC and DC versions), and fully loaded chassis (AC and DC versions)—and the components included in each configuration.

The switch is shipped in only four of these seven configurations: base (AC with 2000 W AC power supplies), base (AC with 3000 W AC power supplies), redundant (AC with 2000 W AC power supplies), and redundant (DC).

Table 1: EX8208 Switch Hardware Configurations

Switch Configuration

Configuration Components

Base configuration (AC with 2000 W AC power supplies)

  • Chassis with backplane
  • One fan tray
  • One Switch Fabric and Routing Engine (SRE) module
  • One Switch Fabric (SF) module
  • Two 2000 W AC power supplies
  • Two power cords
  • Eight line card cover panels
  • Four power supply cover panels

Base configuration (AC with 3000 W AC power supplies)

  • Chassis with backplane
  • One fan tray
  • One Switch Fabric and Routing Engine (SRE) module
  • One Switch Fabric (SF) module
  • Two 3000 W AC power supplies
  • Two power cords
  • Eight line card cover panels
  • Four power supply cover panels

Redundant configuration (AC with 2000 W AC power supplies)

  • Chassis with backplane
  • One fan tray
  • Two SRE modules
  • One SF module
  • Six 2000 W AC power supplies
  • Six power cords
  • Eight line card cover panels

Redundant configuration (DC)

  • Chassis with backplane
  • One fan tray
  • Two SRE modules
  • One SF module
  • Four 2000 W DC power supplies
  • 16 DC power cable lugs
  • Eight line card cover panels

Fully loaded chassis configuration (AC with 2000 W AC power supplies)

  • Chassis with backplane
  • One fan tray
  • Two SRE modules
  • One SF module
  • Six 2000 W AC power supplies
  • Six power cords
  • Eight line cards

Fully loaded chassis configuration (AC with 3000 W AC power supplies)

  • Chassis with backplane
  • One fan tray
  • Two SRE modules
  • One SF module
  • Six 3000 W AC power supplies
  • Six power cords
  • Eight line cards

Fully loaded chassis configuration (DC)

  • Chassis with backplane
  • One fan tray
  • Two SRE modules
  • One SF module
  • Six 2000 W DC power supplies
  • 24 DC power cable lugs
  • Eight line cards

Note: You can install up to eight line cards (any combination of line cards) in the switch.

Note: Line cards are not part of the base or redundant configuration. You must order them separately.

Note: If you want to purchase additional power supplies (AC or DC) for your switch configuration, you must order them separately.


Published: 2010-08-16