Table 1 lists the specifications for the cables that connect to management ports and the wires that connect to the alarm relay contacts.

Table 1: Cable Specifications for Routing Engine Management

Port

Cable Specification

Cable/Wire Supplied

Maximum Length

Router Receptacle

Routing Engine console or auxiliary interface

RS-232 (EIA-232) serial cable

One 6-ft (1.83-m) length with RJ-45/DB-9 connectors

6 ft (1.83 m)

RJ-45 female

Routing Engine Ethernet interface

Category 5 cable or equivalent suitable for 100Base-T operation

One 15-ft (4.57-m) length with RJ-45/RJ-45 connectors

328 ft (100 m)

RJ-45 autosensing