JCS1200 Platform Features and Specifications
Table 1 provides a summary
of the features and specifications of the JCS1200 platform.
Table 1: JCS1200 Features and Specifications
Media tray (on front): - Minimum: One hot-swappable media tray
- Maximum: Two hot-swappable media trays
Each media tray consists of: - Two USB v2.0 ports (output power: 500 mA maximum)
- Front system LED panel
Routing Engine bays (on front): Twelve hot-swappable
Routing Engine (blade) bays Module bays (on front): Module bays (on rear): - Two hot-swappable MUX card bays
- One hot-swappable alarm panel module bay
- Telco alarm connector
- Direct serial connector for Routing Engines
- Rear system LED panel
Power modules: JCS1200 DC platform: - Four DC hot-swappable power modules that provide redundancy
to all JCS1200 components
JCS1200 AC platform: - Four AC hot-swappable power modules that provide redundancy
to all JCS1200 components
| Management module: - Minimum: One hot-swappable management module
- Maximum: Two hot-swappable management modules: one active,
one hot stand-by
Redundant cooling: Four hot-swappable fan module bays (N+1
redundant) Security features: - Login password for remote connection
- Secure Sockets Layer (SSL) security for remote management
access
- ANSI T1.276 enhanced security features
Predictive failure analysis (PFA) alerts: - Fans
- Routing Engine dependent features
Size (12 U): - Height: 21 in. (53.34 cm), minus 8 mm for clearance
- Depth:
- Without optional bezel: 25.64 in. (65.1 cm)
- With optional bezel: 27.80 in. (70.6 cm)
- Width: 17.43 in. (44.3 cm)
- Weight:
- Full configured weight with Routing Engines: Approximately 350 lb (158.8 kg)
- Empty chassis without modules or Routing Engines: Approximately 329 lb (149.6 kg)
| Environment: - Air temperature:
- JCS1200 platform on:
- Altitude: –197 ft to 6000 ft (–60
to 1800 m) 41° to 104° F (5° to 40° C)
- Altitude: 6000 ft to 13000 ft (1800 m to 4000 m) 41°
to 86° F (5° to 30° C)
- JCS1200 platform off: –40° to 70° C
(–40° to 158° F).
- Humidity: 5% to 85%
- Acoustics: declared sound power level: 7.8 bels
Electrical input (N+N redundant): JCS1200 DC platform input voltage (four inputs
at 60-A rating each): - Minimum: –40 V DC
- Maximum: –72 V DC
- DC isolated
JCS1200 AC platform input voltage (four
inputs at 16 A rating each): - Minimum: 180 V AC
- Maximum: 265 V AC
- Sine-wave input (50/60 Hz single-phase)
Heat output: Approximate heat output in British thermal units (Btu) per hour: - JCS1200 DC platform:
- Minimum configuration: 4270 Btu per hour (1251 watts)
- Maximum configuration: 19680 Btu per hour (5766 watts)
- JCS1200 AC platform:
- Minimum configuration: 4175 Btu per hour (1223 watts)
- Maximum configuration: 21850 Btu per hour (6400 watts)
|
Published: 2010-08-02