JCS1200 Alarm Panel Module Interface Connector Electrical Specifications
Table 1 lists the electrical specifications for the JCS1200 alarm panel interface connector.
Table 1: JCS1200 Alarm Panel Interface Connector Electrical Specifications
Item | Specification |
|---|---|
| Outputs | |
Voltage range | 0 V DC to –100 V DC (maximum current 0.3 A at 100 V DC) |
Current range | 0 A to 1 A (maximum voltage 30 V DC at 1 A) |
Worst-case VA | 1 A at –30 V DC (30 VA maximum) indefinitely |
| Inputs | |
Voltage range | 0 V DC to –100 V DC (including transients) |
Differential input voltage | 3 V DC to 72 V DC |
| Reset Input Activation | |
Pulse width | 200 ms (minimum) to 300 ms Note: The reset input resets only the state of the relay contact. The chassis alarm status does not change. |