Channelized OC48/STM16 Enhanced IQ (IQE) PIC with SFP (T640
Router)
Software release | - Junos OS Release 9.4 and later (Type 2)
|
Description | - One OC48/STM16 port
- SONET or SDH is configurable on a per-port granularity
- SONET channelization:
- 4 OC12 channel
- 16 OC3 channels
- 48 DS3 channels
- 672 DS1 channels
- 975 DS0 channels
- SDH channelization:
- 4 STM4 channel
- 16 STM1 channels
- 48 E3 channels
- 504 E1 channels
- 48 DS3 channels (Junos OS Release 10.1 and later)
- 672 DS1 channels (Junos OS Release 10.1 and later)
- 975 DS0 channels
- Power requirement: 1.10 A @ 48V (53 W)
|
Hardware features | |
Software features | |
Cables and connectors | |
LEDs | One tricolor per port: - Off—Not enabled
- Green—Online with no alarms or failures
- Yellow—Online with alarms for remote failures
- Red—Active with a local alarm; router has detected
a failure
|
Alarms, errors, and events | SONET alarms: - Alarm indication signal—line (AIS-L)
- Alarm indication signal—path (AIS-P)
- Bit error rate—signal degrade (BERR-SD)
- Bit error rate—signal fail (BERR-SF)
- Loss of frame (LOF)
- Loss of light (LOL)
- Loss of pointer (LOP)
- Loss of signal (LOS)
- Payload label mismatch (PLM-P)
- Remote defect indication—line (RDI-L)
- Remote defect indication—path (RDI-P)
- Remote error indication (REI)
- Payload unequipped (unequipped STS at path level) (UNEQ-P)
- Virtual container—alarm indication signal (VAIS)
- Virtual container—loss of pointer (VLOP)
- Virtual container—mismatch (VMIS)
- Virtual container—remote defect indication (VRD1)
- Virtual container—unequipped (VUNEQ)
SDH alarms: - Administrative unit alarm indication signal (AU-AIS)
- Bit error rate—signal degrade (BERR-SD)
- Bit error rate—signal fail (BERR-SF)
- Bit interleaved parity (BIP) error B1, B2, B3
- Higher order path—alarm indication signal (HP-AIS)
- Higher order path—far-end receive failure (HP-FERF)
- Higher order path—payload label mismatch (HP-PLM)
- Higher order path—loss of pointer (HP-LOP)
- Higher order path—remote defect indication (HP-RDI)
- Higher order path—unequipped (HP-UNEQ)
- Loss of frame (LOF)
- Loss of light (LOL)
- Loss of signal (LOS)
- Multiplex section—alarm indication signal (MS-AIS)
- Multiplex section—far-end receive failure (MS-FERF)
- Multiplex section—remote defect indication (MS-RDI)
- Multiplex section—remote error indication (MS-REI)
- Phase lock loop (PLL)
- Remote error indication (REI)
- Severely errored frame (SEF)
- Tributary unit—alarm indication signal (TU-AIS)
- Tributary unit—loss of pointer (TU-LOP)
- Tributary unit—mismatch (TU-MIS)
- Tributary unit—remote defect indication (TU-RD1)
- Tributary unit—unequipped (TU-UNEQ)
DS1 alarms: - Alarm indication signal (AIS)
- Loss of frame (LOF)
- Remote alarm indication signal (RAIS)
DS1 error detection: - Bursty errored seconds (BES)
- CRC errors
- Errored seconds (ES)
- Line errored seconds (LES)
- Loss of framing seconds (LOFS)
- Severely errored seconds (SES)
- Severely errored framing seconds (SEFS)
- Unavailable seconds (UAS)
DS3 alarms: - Alarm indication signal (AIS)
- Loss of frame (LOF)
- Yellow alarm
DS3 error detection: - C-bit code violations (CCV)
- C-bit errored seconds (CES)
- C-bit severely errored framing seconds (CEFS)
- CRC errors
- Excessive zeros (EXZ)
- Far-end block error (FEBE)
- Far-end receive failure (FERF)
- Line errored seconds (LES)
- Parity bit (P-bit) code violations (PCV)
- Parity bit (P-bit) errored seconds (PES)
- Parity bit (P-bit) severely errored framing seconds (PSES)
- Severely errored framing seconds (SEFS)
- Unavailable seconds (UAS)
|
Instrumentation (counters) | - Layer 2 per-queue and per-channel packet and byte counters
|
Table 1: PICs
Supported in Fourth Slot of T640-FPC2-E and T640-FPC2-E2 with Type
2 IQE PICs
PIC Name | PIC Model Number |
|---|
Gigabit Ethernet, 2-port SFP | PB-2GE-SFP |
Gigabit Ethernet, 4-port SFP | PB-4GE-SFP |
Gigabit Ethernet IQ, 2-port SFP | PB-2GE-SFP-QPP |
SONET/SDH OC12c/STM4, 4-port with multimode transceivers
installed | PB-4OC12-SON-MM |
SONET/SDH OC12c/STM4, 4-port with single-mode intermediate
reach transceivers installed | PB-4OC12-SON-SMIR |
SONET/SDH OC48/STM16, 1-port SFP | PB-1OC48–SON-SFP |
Tunnel Services | PB-TUNNEL |
Published: 2010-08-11