Description | - Ten E1 or T1 ports
- DS1 and E1 interfaces are selectable on a per-port granularity
- E1 channelization per PIC:
- 10 E1 channels
- 310 DS0 channels
- T1 channelization per PIC:
- 10 T1 channels
- 240 DS0 channels
- Power requirement: 0.52 A @ 48 V (24.73 W)
|
Hardware features | Port numbering:
- Top row: 0 and 1 from left to right
- Second row: 2 and 3 from left to right
- Third row: 3 and 4 from left to right
- Bottom row: 5 and 6 from left to right
|
Software features | |
Cables and connectors | - 120-ohm RJ-48C connector (female)
|
LEDs | One tricolor per port: - Off—Not enabled
- Green—Online with no alarms or failures
- Yellow—Online with alarms for remote failures
- Red—Active with a local alarm; router has detected
a failure
|
Alarms, errors, and events | DS1 alarms: - Alarm indication signal (AIS)
- Loss of frame (LOF)
- Remote alarm indication signal (RAIS)
- 24-hour alarm reporting history maintained for error statistics
and failure counts, 15-minute intervals on all errors
DS1 error detection: - Bursty errored seconds (BES)
- CRC errors
- Errored seconds (ES)
- Line errored seconds (LES)
- Loss of framing seconds (LOFS)
- Loss of signal seconds (LOSS)
- Severely errored seconds (SES)
- Severely errored framing seconds (SEFS)
- Unavailable seconds (UAS)
|
Instrumentation (counters) | - Layer 2 per-queue and per-channel packet and byte counters
- Layer 2 per-queue and per-channel packet and byte drop
counters
|