Description | - Four DS3 or E3 ports
- DS3 or E3 is configurable on a per-port granularity
- Power requirement: 0.51 A @ 48 V (24.7 W)
|
Hardware features | - Ports are numbered 0 through 3 top to bottom
|
Software features | |
Cables and connectors | - Standard DS3 BNC coaxial cable interfaces
|
LEDs | One tricolor per port: - Off—Not enabled
- Green—Online with no alarms or failures
- Yellow—Online with alarms for remote failures
- Red—Active with a local alarm; router has detected
a failure
|
Alarms, errors, and events | DS3 alarms: - Alarm indication signal (AIS)
- Loss of frame (LOF)
- Loss of signal (LOS)
- Phase lock loop (PLL)
DS3 error detection: - C-bit code violations (CCV)
- C-bit errored seconds (CES)
- C-bit severely errored framing seconds (CEFS)
- CRC errors
- Excessive zeros (EXZ)
- Far-end block error (FEBE)
- Far-end receive failure (FERF)
- Line errored seconds (LES)
- Parity bit (P-bit) code violations (PCV)
- Parity bit (P-bit) errored seconds (PES)
- Parity bit (P-bit) severely errored framing seconds (PSES)
- Severely errored framing seconds (SEFS)
- Unavailable seconds (UAS)
|
Instrumentation (counters) | - Layer 2 per-queue and per-channel packet and byte counters
|