Description | |
Hardware features | - Subrate and scrambling:
- Digital Link/Quick Eagle
- Kentrox
- Larscom
- ADTRAN
- Verilink
- M13/C-bit parity encoding
- Local and remote loopback testing
|
Software features | - Loop timing and external timing
- Optical diagnostics
- AM1 or B8ZS line encoding
- APS/SDH MSP
- Fractional mode and framed clear channel mode
- Superframe (D4/SF) and extended superframe (ESP) framing
- Simple Network Management Protocol (SNMP):
- OC3 MIB
- T1 MIB
- ATM MIB (Junos OS Release 10.2 and later)
- Automatic protection switching (APS)
- Dynamic, arbitrary channel configuration
- Full bit error rate test (BERT)
- Encapsulations: Structure-agnostic time-division multiplexing
(TDM) over packet (SAToP) (RFC 4553)
- Pseudowire emulation edge-to-edge (PWE3) for ATM (RFC
4717) (Junos OS Release 9.6 and later)
- ATM Pseudowire emulation edge-to-edge via dynamic labels
(LDP, RSVP-TE) (Junos OS Release 9.6 and later)
- Inverse mulitplexing (IMA) for ATM (Junos OS Release 10.0
and later)
- ATM QoS for the Junos OS Release 10.2 and later:
- Per-virtual circuit (VC) and per-virtual path (VP) traffic
shaping
- Unspecified bit rate (UBR) traffic shaping
- Fine-grained real-time variable bit rate (rtVBR) and real-time
variable bit rate (nrtVBR) traffic shaping
- Port-level egress shaping
- Constant bit rate (CBR)
- Policing on a per virtual circuit basis
- Independent peak cell rate (PCR) and sustained cell rate
(SCR) policing
- Counting, tagging, or discard policing actions
|
Cables and connectors | |
LEDs | OK LED, one tricolor: - Off—PIC is offline and it is safe to remove it from
the router.
- Green—PIC is operating normally.
- Yellow—PIC is initializing.
- Red—PIC has an error or failure.
APP LED, one bicolor: - Off—Monitoring application is not running.
- Green—Monitoring application is running under acceptable
load.
One tricolor per port: - Off—Not enabled
- Green—Online with no alarms or failures
- Yellow—Online with alarms for remote failures
- Red—Active with a local alarm; router has detected
a failure
|
Alarms, errors, and events | Structure-agnostic alarms for
T1 interface: - Alarm indication signal (AIS-L, AIS-P)
- Loss of signal (LOS)
- Errored seconds (ES)
- Line-errored seconds (LES)
- Severely errored seconds (SES)
- Unavailable errored seconds (UAS)
- Bipolar violation (BPV)
- Controlled slip (CS)
- Line code violation (LCV)
Structure-agnostic alarms for E1 interface: - Alarm indication signal (AIS-L, AIS-P)
- Loss of signal (LOS)
- Errored seconds (ES)
- Line-errored seconds (LES)
- Severely errored seconds (SES)
- Unavailable errored seconds (UAS)
- Bipolar violation (BPV)
- Controlled slip (CS)
- Line code violation (LCV)
|