Description | |
Hardware features | - Maximum transmission units (MTUs) of up to 1024 bytes
- Per-interface diagnostics and loopback control
- Per-interface alarm and event counting and detection
- Framing
- 4-bit CRC for G.704 framed mode
- G.704 without CRC4
- Unframed
- Balanced and unbalanced modes
- Full bit error rate test (BERT)
|
Software features | - PIC can be configured as twelve T1 ports or twelve E1
ports
- Local and remote loopback diagnostics
- E1 ports
- T1 ports
- High-performance throughput on each port at speeds up
to 1544 Mbps, full duplex
- AMI and B8ZS line encoding
- Framed clear channel mode
- Fractional mode
- Superframe (D4/SF) and extended superframe (ESF) framing
- ESF CSU counters, WRT impairments, and CRC checking
- Local DS1 line loopback, remote line loopback
- Loop timing and PIC line timing
- Encapsulations: Structure-agnostic time-division multiplexing
(TDM) over packet (SAToP) (RFC 4553)
- Pseudowire emulation edge-to-edge (PWE3) for ATM (RFC
4717) (Junos OS Release 9.6 and later)
- ATM Pseudowire emulation edge-to-edge via dynamic labels
(LDP, RSVP-TE) (Junos OS Release 9.6 and later)
- Inverse mulitplexing (IMA) for ATM (Junos OS Release 10.0
and later)
- Simple Network Management Protocol (SNMP): ATM MIB (Junos
OS Release 10.2 and later)
- ATM QoS (Junos OS Release 10.2 and later)
- Per-virtual circuit (VC) and per-virtual path (VP) traffic
shaping
- Unspecified bit rate (UBR) traffic shaping
- Fine-grained real-time variable bit rate (rtVBR) and real-time
variable bit rate (nrtVBR) traffic shaping
- Port-level egress shaping
- Constant bit rate (CBR)
- Policing on a per virtual circuit basis
- Independent peak cell rate (PCR) and sustained cell rate
(SCR) policing
- Counting, tagging, or discard policing actions
|
Cables and connectors | - RJ-21 connector
- Cables are rated for intra-building connections only.
|
LEDs | OK LED, one tricolor: - Off—PIC is offline and it is safe to remove it from
the router.
- Green—PIC is operating normally.
- Yellow—PIC is initializing.
- Red—PIC has an error or failure.
APP LED, one bicolor: - Off—Monitoring application is not running.
- Green—Monitoring application is running under acceptable
load.
One tricolor per port: - Off—Not enabled
- Green—Online with no alarms or failures
- Yellow—Online with alarms for remote failures
- Red—Active with a local alarm; router has detected
a failure
|
Alarms, errors, and events | Structure agnostic
alarms for T1: - Alarm indication signal (AIS)
- Loss of signal (LOS)
- Errored seconds (ES)
- Line code violation (LCV)
- Line errored seconds (LES)
- Severely errored seconds (SES)
- Unavailable seconds (UAS)
Structure agnostic alarms
for E1: - Alarm indication signal (AIS)
- Errored seconds (ES)
- Line code violation (LCV)
- Line errored seconds (LES)
- Severely errored seconds (SES)
- Unavailable seconds (UAS)
Structure aware alarms for
E1: - Alarm indication signal (AIS)
- Loss of frame (LOF)
- Loss of signal (LOS)
- Yellow alarm (remote alarm indication (RAI) (YLW)
- Far-end block error (FEBE)
- Cylical Redundancy Check (CRC)
- CRC major
- CRC minor
- Line code violation (LCV)
- Path code violation (LCV)
- Errored seconds (ES)
- Bursty errored seconds (BES)
- Line errored seconds (LES)
- Severely errored seconds (SES)
- Severely errored frame seconds (SEFS)
- Unavailable seconds (UAS)
|