Technical Documentation

T1600 Field-Replaceable Units

Field-replaceable units (FRUs) are router components that can be replaced at the customer site. Replacing most FRUs requires minimal router downtime. The router uses the following types of FRUs:

  • Hot-removable and hot-insertable FRUs—You can remove and replace these components without powering off the router or disrupting the routing functions.
  • Hot-pluggable FRUs—You can remove and replace these components without powering down the router, but the routing functions of the system are interrupted when the component is removed.

Before you replace a component in the host subsystem, you must take the host subsystem offline.

Table 1 lists the FRUs for the router.

Table 1: Field-Replaceable Units

Hot-Removable and Hot-Insertable FRUs

Hot-Pluggable FRUs

Air filters

Flexible PIC Concentrators (FPCs)

Front and rear fan trays

PICs

Redundant power supplies

Master SONET Clock Generators (SCG)

Switch Interface Boards (T1600-SIBs or TXP-T1600 SIBs)

Backup control board (T-CB or LCC-CB)

Master control board (T-CB or LCC-CB) (if nonstop active routing is configured)

Backup Routing Engine

Master Routing Engine (if nonstop active routing is configured)

Connector Interface Panel (CIP)

Nonredundant control boards (T-CB and LCC-CB)

Master control board (T-CB or LCC-CB) (if nonstop active routing is not configured)

Nonredundant Routing Engine

Master Routing Engine (if nonstop active routing is not configured)

Master SONET Clock Generator (SCG)

Nonredundant SONET Clock Generator (SCG)