show pfe statistics traffic egress-queues
Syntax
Release Information
Command introduced in Junos OS Release 9.5 for EX Series switches.
Description
(On EX8200 switches only) Display count of multidestination packets dropped on egress ports when the egress queues are oversubscribed due to multidestination traffic.
![]() | Note: Multidestination packets include unknown unicast, broadcast, and multicast packets. |
Options
- none
Displays count of packets dropped on egress ports of all physical interfaces (line cards) when egress queues are oversubscribed due to multidestination traffic.
- fpc fpc-slot
(Optional) Displays count of packets dropped on egress ports of the physical interface (line card) referred to by the slot number.

Note: On an EX8200 switch, the FPC slot number is the slot number for the line card. Possible values are 0 through 7 on the EX8208 switch and 0 through 15 on the EX8216 switch.
Required Privilege Level
view
Related Topics
List of Sample Output
show pfe statistics traffic egress-queues fpc 4 (EX8208 Switch)Output Fields
Table 1 lists the output fields for the show pfe statistics traffic egress-queues command. Output fields are listed in the approximate order in which they appear.
Table 1: show pfe statistics traffic egress-queues Output Fields
Field Name | Field Description |
|---|---|
Tail-dropped packets | Number of arriving packets dropped because the output queue buffers are full. |
Sample Output
show pfe statistics traffic egress-queues fpc 4 (EX8208 Switch)
user@switch> show pfe statistics traffic egress-queues
fpc 4Tail-dropped packets : 0