UI System Log Messages
This chapter describes messages with the UI prefix. They are generated by the Junos OS command-line interface (CLI) and management process (mgd), which together form the Junos user interface that accepts and processes input from users and client applications.
UI_AUTH_EVENT
System Log Message
Authenticated user 'username' at permission level 'authentication-level'
Description
The management process (mgd) authenticated the indicated user.
Type
Event: This message reports an event, not an error
Severity
info
Facility
LOG_AUTH
UI_AUTH_INVALID_CHALLENGE
System Log Message
Received invalid authentication challenge for user 'username': response
Description
When a user logs onto the routing platform and attempts to authenticate, the CLI and management process (mgd) use a challenge-and-response system to limit the exposure of sensitive information such as passwords and keys. The format of the challenge generated by mgd was incorrect.
Type
Error: An error occurred
Severity
error
Facility
LOG_USER
Cause
An internal software failure occurred.
Action
Contact your technical support representative.
UI_BOOTTIME_FAILED
System Log Message
Unable to fetch boot time: error-message
Description
The management process (mgd) could not retrieve the system boot time from the kernel.
Type
Error: An error occurred
Severity
error
Facility
ANY
Cause
An internal software failure occurred.
Action
Contact your technical support representative.
UI_CFG_AUDIT_NEW
System Log Message
User 'username' action: pathname new-name
Description
The indicated user created a new configuration object by copying or renaming an existing object as indicated.
Type
Event: This message reports an event, not an error
Severity
info
Facility
ANY
UI_CFG_AUDIT_OTHER
System Log Message
User 'username' action: pathname delimitervalue
Description
The indicated user deleted, activated, or deactivated a configuration object, as indicated. The JUNOS configuration log facility logged the change.
Type
Event: This message reports an event, not an error
Severity
info
Facility
ANY
UI_CFG_AUDIT_SET
System Log Message
User 'username' action: pathname delimiterdata -> "value"
Description
The indicated user set a value for a configuration object, as indicated.
Type
Event: This message reports an event, not an error
Severity
info
Facility
ANY
UI_CFG_AUDIT_SET_SECRET
System Log Message
User 'username' action: pathname
Description
The indicated user set a value for a configuration object, as indicated. For security, the actual value (which might be an authentication key or password, for example) is not recorded.
Type
Event: This message reports an event, not an error
Severity
info
Facility
ANY
UI_CHILD_ARGS_EXCEEDED
System Log Message
Too many arguments for child process 'command'
Description
The management process (mgd) invokes some commands on behalf of users. It supplied more arguments than the command's syntax statement specifies.
Type
Error: An error occurred
Severity
error
Facility
ANY
Cause
An internal software failure occurred.
Action
Contact your technical support representative.
UI_CHILD_CHANGE_USER
System Log Message
Unable to switch to local user: username
Description
The management process (mgd) invokes some commands on behalf of users. Its attempt to adopt the UID of the indicated user failed.
Type
Error: An error occurred
Severity
error
Facility
ANY
Cause
An internal software failure occurred.
Action
Contact your technical support representative.
UI_CHILD_EXEC
System Log Message
Child exec failed for command 'command': error-message
Description
The management process (mgd) invoked the exec() system call while creating a child processes to execute the indicated command on its behalf. The system call failed.
Type
Error: An error occurred
Severity
error
Facility
ANY
Cause
An internal software failure occurred.
Action
Contact your technical support representative.
UI_CHILD_EXITED
System Log Message
Child exited: PID pid, status return-valuecore-dump-status, command 'command'
Description
The management process (mgd) created a child process to execute the indicated command for it. The child process exited unexpectedly with the indicated status code.
Type
Error: An error occurred
Severity
notice
Facility
ANY
Cause
An internal software failure occurred.
Action
Contact your technical support representative.
UI_CHILD_FOPEN
System Log Message
Unable to append to log 'filename': error-message
Description
The management process (mgd) attempted to save the output from a command in the indicated log file, but could not open the file.
Type
Error: An error occurred
Severity
error
Facility
ANY
Cause
An internal software failure occurred.
Action
Contact your technical support representative.
UI_CHILD_PIPE_FAILED
System Log Message
Unable to create pipe for command 'command': error-message
Description
The management process (mgd) created a child process to execute the indicated command for it. Its attempt to create pipes for communication with the child process failed.
Type
Error: An error occurred
Severity
error
Facility
ANY
Cause
An internal software failure occurred.
Action
Contact your technical support representative.
UI_CHILD_STOPPED
System Log Message
Child stopped: PID pid, signal=signal-namecore-dump-status, command='command')
Description
The management process (mgd) created a child process to execute the indicated command for it. The child process received the indicated signal and stopped.
Type
Error: An error occurred
Severity
notice
Facility
ANY
Cause
An internal software failure occurred.
Action
Contact your technical support representative.
UI_CHILD_WAITPID
System Log Message
waitpid failed: PID pid, rc return-value, status status-code: error-message
Description
The management process (mgd) created a child process to execute a command for it. It could not wait for the child process to finish.
Type
Error: An error occurred
Severity
error
Facility
ANY
Cause
An internal software failure occurred.
Action
Contact your technical support representative.
UI_CMDLINE_READ_LINE
System Log Message
User 'username', command 'command'
Description
The indicated user typed the indicated command at the CLI prompt and pressed the Enter key, sending the command string to the management process (mgd).
Type
Event: This message reports an event, not an error
Severity
info
Facility
LOG_AUTH
UI_CMD_AUTH_REGEX_INVALID
System Log Message
Invalid 'allow-deny' command authorization regular expression 'regular-expression': error-message
Description
An operation that attempted to set command or configuration authorization included the indicated regular expression. The operation failed because the expression syntax was invalid.
Type
Error: An error occurred
Severity
error
Facility
ANY
Action
Correct any errors in the regular expression.
UI_COMMIT
System Log Message
User 'username' requested 'command' operation (comment: message)
Description
The indicated user requested the indicated type of commit operation on the candidate configuration and added the indicated comment. The 'commit' operation applies to the local Routing Engine and the 'commit synchronize' operation to both Routing Engines.
Type
Event: This message reports an event, not an error
Severity
notice
Facility
ANY
UI_COMMIT_AT_ABORT
System Log Message
reason, will try again
Description
An attempt to complete a pending commit operation was cancelled for the indicated reason.
Type
Error: An error occurred
Severity
error
Facility
ANY
UI_COMMIT_AT_COMPLETED
System Log Message
'commit at' was successful
Description
Changes to the candidate configuration were activated at the time scheduled by a 'commit at' operation.
Type
Event: This message reports an event, not an error
Severity
notice
Facility
ANY
UI_COMMIT_AT_FAILED
System Log Message
reason, scheduled commit cleared
Description
A 'commit at' operation did not complete, for the indicated reason.
Type
Error: An error occurred
Severity
error
Facility
ANY
UI_COMMIT_COMPRESS_FAILED
System Log Message
Unable to compress file 'filename'
Description
As part of committing a new configuration, the management process (mgd) compresses and saves a copy of the configuration. mgd saved the configuration file in regular format because it could not compress it.
Type
Error: An error occurred
Severity
error
Facility
ANY
Cause
The Routing Engine is low on resources.
Cause
An internal software failure occurred.
Action
Contact your technical support representative.
UI_COMMIT_CONFIRMED_REMINDER
System Log Message
'commit confirmed' must be confirmed within duration minutes
Description
A 'commit confirmed' operation has activated the candidate configuration temporarily. If the commit is not confirmed within the indicated number of minutes (for example, by the command-line interface (CLI) 'commit' command), the management process (mgd) will roll back to the previous configuration.
Type
Event: This message reports an event, not an error
Severity
notice
Facility
ANY
UI_COMMIT_EMPTY_CONTAINER
System Log Message
Skipped empty object 'node-name'
Description
Some container objects are marked for automatic removal from the configuration hierarchy if they are empty when the user who created them changes to the top ([edit]) level of the hierarchy or exits configuration mode. While committing the candidate configuration, the management process (mgd) encountered such an object that was empty but not removed.
Type
Event: This message reports an event, not an error
Severity
info
Facility
ANY
Cause
When the commit operation began, the user who created the new container object had not populated it and was in configuration mode but not at the top level of the hierarchy.
Action
Populate or remove the empty object before committing the configuration. The user who created the object can remove it by exiting configuration mode or issuing the 'top' command to move to the top level of the hierarchy.
UI_COMMIT_NOT_CONFIRMED
System Log Message
Commit was not confirmed; message
Description
The 'commit confirmed' operation commits a configuration but requires confirmation within a defined number of minutes for the commit to become permanent. If the commit is not confirmed (by the 'commit' command, for example), the management process (mgd) automatically rolls back to the previously committed configuration. The automatic rollback restores management access to the routing platform in case an error in the configuration blocks access.
Type
Event: This message reports an event, not an error
Severity
notice
Facility
LOG_AUTH
UI_COMMIT_PROGRESS
System Log Message
Commit operation in progress: message
Description
As it performed a commit operation, the management process (mgd) recorded its execution of the indicated step.
Type
Event: This message reports an event, not an error
Severity
info
Facility
ANY
UI_COMMIT_ROLLBACK_FAILED
System Log Message
Automatic rollback failed
Description
The 'commit confirmed' operation commits a configuration but requires confirmation within a defined number of minutes for the commit to become permanent. If the commit is not confirmed (by the 'commit' command, for example), the management process (mgd) automatically rolls back to the previously committed configuration. The 'commit confirmed' operation was not confirmed, but mgd could not roll back the configuration. The configuration might be in an indeterminate state.
Type
Error: An error occurred
Severity
error
Facility
LOG_AUTH
Cause
The cause of the problem might be recorded in messages that precede this message in the system log.
UI_COMMIT_SYNC_FORCE
System Log Message
All logins to local configuration database were terminated because forced 'commit synchronize' operation was invoked on other Routing Engine
Description
The 'commit synchronize force' command was issued on the other Routing Engine on the router. All login sessions in the local configuration database were terminated and the configuration from the other Routing Engine was committed on the local Routing Engine.
Type
Event: This message reports an event, not an error
Severity
notice
Facility
ANY
UI_CONFIGURATION_ERROR
System Log Message
Process: process-name, path: pathname, statement: configuration-statement, error-message
Description
The indicated process found a problem in its configuration.
Type
Error: An error occurred
Severity
error
Facility
ANY
UI_CONFIGURATION_WARNING
System Log Message
Process: process-name, path: pathname, statement: configuration-statement, warning-message
Description
The indicated process found a problem in its configuration.
Type
Error: An error occurred
Severity
warning
Facility
ANY
UI_DAEMON_ACCEPT_FAILED
System Log Message
connection-type socket connection accept failed: error-message
Description
The management process (mgd) did not accept an incoming connection request.
Type
Error: An error occurred
Severity
error
Facility
LOG_AUTH
Cause
An internal software failure occurred.
Action
Contact your technical support representative.
UI_DAEMON_FORK_FAILED
System Log Message
Unable to create session child: error-message
Description
The management process (mgd) invokes the fork() system call to create a copy of itself for each CLI session. The system call failed.
Type
Error: An error occurred
Severity
error
Facility
LOG_AUTH
Cause
An internal software failure occurred.
Action
Contact your technical support representative.
UI_DAEMON_SELECT_FAILED
System Log Message
select failed: error-message
Description
The management process (mgd) uses the select() system call to listen for incoming connection requests on a socket. The system call failed.
Type
Error: An error occurred
Severity
error
Facility
LOG_AUTH
Cause
An internal software failure occurred.
Action
Contact your technical support representative.
UI_DAEMON_SOCKET_FAILED
System Log Message
connection-type socket create failed: error-message
Description
The management process (mgd) uses sockets to communicate with other Junos OS processes running on the routing platform. It could not allocate a socket.
Type
Error: An error occurred
Severity
error
Facility
LOG_AUTH
Cause
System resources are exhausted.
Action
Contact your technical support representative.
UI_DBASE_ACCESS_FAILED
System Log Message
Unable to reaccess configuration database file 'filename', address address, size size: reason
Description
To increase the size of the configuration database, the management process (mgd) must unmap the database from its address space, change the database size, and remap the database. The remapping operation failed.
Type
Error: An error occurred
Severity
error
Facility
ANY
Cause
An internal software failure occurred.
Action
Contact your technical support representative.
UI_DBASE_CHECKOUT_FAILED
System Log Message
Database 'filename' is out of data and needs to be rebuilt
Description
When the routing platform boots, the management process (mgd) checks the configuration database for internal consistency. It found one or more inconsistencies.
Type
Event: This message reports an event, not an error
Severity
alert
Facility
ANY
Cause
mgd restarted after new JUNOS software was installed.
Action
None; mgd will rebuild the database.
UI_DBASE_EXTEND_FAILED
System Log Message
Unable to extend configuration database file 'filename' to size requested-size: reason
Description
The management process (mgd) could not increase the configuration database to the indicated size.
Type
Error: An error occurred
Severity
error
Facility
ANY
Cause
The hard disk is defective or is not installed in the routing platform.
Action
Repair or replace the hard disk.
Cause
There is insufficient disk space on the /var partition on the hard disk.
Action
Delete user files from the /var/homes directory to increase the available disk space.
UI_DBASE_LOGIN_EVENT
System Log Message
User 'username' entering configuration mode
Description
The indicated user entered configuration mode (logged into the configuration database).
Type
Event: This message reports an event, not an error
Severity
notice
Facility
ANY
UI_DBASE_LOGOUT_EVENT
System Log Message
User 'username' exiting configuration mode
Description
The indicated user exited configuration mode (logged out of the configuration database).
Type
Event: This message reports an event, not an error
Severity
notice
Facility
ANY
UI_DBASE_MISMATCH_EXTENT
System Log Message
Database header extent mismatch for file 'filename': expecting expected-value, got received-value
Description
The header in the configuration database records the highest address allocated in the database. The management process (mgd) discovered that the highest address actually allocated in the database does not match the header value.
Type
Error: An error occurred
Severity
error
Facility
ANY
Cause
The database file is corrupted.
Action
Contact your technical support representative.
UI_DBASE_MISMATCH_MAJOR
System Log Message
Database header major version number mismatch for file 'filename': expecting expected-value, got received-value
Description
For compatibility, the version number recorded in the header of the configuration database must match the version of JUNOS software running on the routing platform. The management process (mgd) discovered that the major parts (for example, '5' in '5.x') of the version numbers do not match.
Type
Error: An error occurred
Severity
error
Facility
ANY
Cause
A recent software upgrade did not complete successfully.
Action
Issue the 'show version' command to check the JUNOS version. If necessary, issue the 'request system reboot' command to reboot the routing platform and complete the software installation.
Cause
The database file is corrupted.
Action
Contact your technical support representative.
UI_DBASE_MISMATCH_MINOR
System Log Message
Database header minor version number mismatch for file 'filename': expecting expected-value, got received-value
Description
For compatibility, the version number recorded in the header of the configuration database must match the version of JUNOS software running on the routing platform. The management process (mgd) discovered that the minor parts (for example, '2' in 'x.2') of the version numbers do not match.
Type
Error: An error occurred
Severity
error
Facility
ANY
Cause
A recent software upgrade did not complete successfully.
Action
Issue the 'show version' command to check the JUNOS version. If necessary, issue the 'request system reboot' command to reboot the routing platform and complete the software installation.
Cause
The database file is corrupted.
Action
Contact your technical support representative.
UI_DBASE_MISMATCH_SEQUENCE
System Log Message
Database header sequence numbers mismatch for file 'filename'. If a package has just been added or deleted, please verify and commit the configuration.
Description
The header of the configuration database records the version number of the configuration schema (possible set of statements) used when the database was created. To prevent corruption, all JUNOS processes that access the database must use the same schema. The management process (mgd) discovered that the version number for the JUNOS software installed on the routing platform does not match the header value.
Type
Error: An error occurred
Severity
warning
Facility
ANY
Cause
A recent software upgrade did not complete successfully.
Action
Issue the 'show version' command to check the JUNOS version. If necessary, issue the 'request system reboot' command to reboot the routing platform and complete the software installation.
Cause
The database file is corrupted.
Action
Contact your technical support representative.
UI_DBASE_MISMATCH_SIZE
System Log Message
Database header size mismatch for file 'filename': expecting expected-valuex, got received-value
Description
The header of the configuration database records the database size. The management process (mgd) discovered that the size of the actual database file does not match the header value.
Type
Error: An error occurred
Severity
error
Facility
ANY
Cause
The database file is corrupted.
Action
Contact your technical support representative.
UI_DBASE_OPEN_FAILED
System Log Message
Database open failed for file 'filename': reason
Description
The management process (mgd) could not open the indicated configuration database file.
Type
Error: An error occurred
Severity
error
Facility
ANY
Cause
The database file does not exist.
Action
Select a different filename or create a new configuration.
Cause
The /config directory does not have sufficient space for a new database.
Action
Remove files from the /config directory to make more space available.
UI_DBASE_REBUILD_FAILED
System Log Message
modeusername rebuild of the database 'filename' failed
Description
The management process (mgd) could not rebuild the configuration database file.
Type
Error: An error occurred
Severity
alert
Facility
ANY
Cause
An internal software failure occurred.
Action
Contact your technical support representative.
UI_DBASE_REBUILD_SCHEMA_FAILED
System Log Message
Automatic rebuild of the database failed
Description
The management process (mgd) could not rebuild the schema for the configuration database.
Type
Error: An error occurred
Severity
alert
Facility
ANY
Cause
An internal software failure occurred.
Action
Contact your technical support representative.
UI_DBASE_REBUILD_STARTED
System Log Message
modeusername rebuild/rollback of the database 'filename' started
Description
The management process (mgd) began to rebuild the configuration database file or its schema because that object was not current. The operation will complete shortly.
Type
Event: This message reports an event, not an error
Severity
alert
Facility
ANY
UI_DBASE_RECREATE
System Log Message
User 'username' attempting database re-creation
Description
The management process (mgd) discovered that the version of JUNOS software running on the routing platform does not match the version of the current configuration database. In response to a prompt from mgd, the indicated user initiated a rebuilding of the database.
Type
Event: This message reports an event, not an error
Severity
notice
Facility
ANY
UI_DBASE_REOPEN_FAILED
System Log Message
Reopen of the database failed
Description
After rebuilding the schema file for the configuration database, the management process (mgd) closes the file and reopens it in read-only mode to prevent corruption. It could not reopen the file.
Type
Error: An error occurred
Severity
alert
Facility
ANY
Cause
An internal software failure occurred.
Action
Contact your technical support representative.
UI_DUPLICATE_UID
System Log Message
Users username1 and username2 have the same UID uid
Description
The JUNOS software allows multiple user login accounts to share the same UID. This message was logged in case site policy dictates that users should not share UIDs.
Type
Event: This message reports an event, not an error
Severity
notice
Facility
ANY
Action
Assign different UIDs to the affected users.
UI_FACTORY_OPERATION
System Log Message
Committing factory default configuration because CONFIG button was pressed and held
Description
The management process (mgd) began a commit operation to activate the factory default configuration, because the CONFIG button on the chassis was pressed and held for 15 seconds or more.
Type
Event: This message reports an event, not an error
Severity
notice
Facility
LOG_AUTH
UI_INITIALSETUP_OPERATION
System Log Message
Committing EZsetup configuration as EZsetup option is chosen
Description
The management process (mgd) began a commit operation to activate the pre initial setup configuration, because the initial-setup option was selected from the LCD Menu.
Type
Event: This message reports an event, not an error
Severity
notice
Facility
LOG_AUTH
UI_INVALID_REMOTE_PERMISSION
System Log Message
invalid permissions from authorization server: permission-name
Description
RADIUS and TACACS+ authorization servers use Juniper Networks vendor-specific attributes (VSAs) to specify user permissions. A VSA included the indicated permission name, which is invalid.
Type
Error: An error occurred
Severity
error
Facility
ANY
UI_JUNOSCRIPT_CMD
System Log Message
User 'username' used JUNOScript client to run command 'command'
Description
The indicated user ran the indicated command using the JUNOS XML management protocol.
Type
Event: This message reports an event, not an error
Severity
info
Facility
LOG_AUTH
UI_JUNOSCRIPT_ERROR
System Log Message
JUNOScript error: error-message
Description
The management process (mgd) normally sends an error message to the JUNOS CLI or JUNOScript API client in an <xnm:error> tag. It could not send the tag, so it sent the indicated error message in an XML comment instead.
Type
Error: An error occurred
Severity
warning
Facility
ANY
UI_LCC_NO_MASTER
System Log Message
No master Routing Engine defined for LCClcc
Description
By default, the Junos OS installed on the TX Matrix platform in a routing matrix is automatically copied to and installed on all T640 routing nodes in the routing matrix. The software was not installed on the indicated T640 routing node (line-card chassis, or LCC), because the management process (mgd) on the TX Matrix platform could not determine which Routing Engine on the LCC was the master.
Type
Error: An error occurred
Severity
error
Facility
LOG_AUTH
Action
Resolve the mastership situation on the T640 routing node and install the software on its Routing Engines.
UI_LOAD_EVENT
System Log Message
User 'username' is performing a 'operation'
Description
The indicated user requested the indicated operation ('rollback, ' or 'load' or one of its variants) on the configuration database. The existing configuration database was deleted and a new database was created based on a text file.
Type
Event: This message reports an event, not an error
Severity
notice
Facility
ANY
UI_LOAD_JUNOS_DEFAULT_FILE_EVENT
System Log Message
Loading the default config from pathname
Description
The system is loading junos default configuration from file.
Type
Event: This message reports an event, not an error
Severity
info
Facility
ANY
UI_LOGIN_EVENT
System Log Message
User 'username' login, class 'class-name' local-peer[pid], ssh-connection 'ssh-connection', client-mode 'client-mode'
Description
The indicated user started a JUNOS CLI session.
Type
Event: This message reports an event, not an error
Severity
info
Facility
ANY
UI_LOGOUT_EVENT
System Log Message
User 'username' logout
Description
The indicated user exited from a JUNOS CLI session.
Type
Event: This message reports an event, not an error
Severity
info
Facility
ANY
UI_LOST_CONN
System Log Message
Lost connection to daemon 'process-name'
Description
The management process (mgd) uses sockets to communicate with other JUNOS software processes. The socket it was using for the indicated process closed prematurely.
Type
Error: An error occurred
Severity
error
Facility
ANY
Cause
An internal software failure occurred.
Action
Contact your technical support representative.
UI_MASTERSHIP_EVENT
System Log Message
mastership-event card-name mastership by 'username'
Description
Some redundant routing platform components use a master/standby system in which the master component is active and the standby is inactive but ready to assume mastership. The indicated user performed the indicated operation to modify component mastership.
Type
Event: This message reports an event, not an error
Severity
warning
Facility
LOG_AUTH
UI_MOTD_PROPAGATE_ERROR
System Log Message
Unable to propagate login announcement (motd) to pathname
Description
The management process (mgd) could not create or write to the indicated file, which was the intended location for the message of the day (MOTD) configured at the [edit system login announcement] hierarchy level.
Type
Error: An error occurred
Severity
error
Facility
ANY
UI_NETCONF_CMD
System Log Message
User 'username' used NETCONF client to run command 'command'
Description
The indicated user ran the indicated command using the NETCONF application programming interface (API).
Type
Event: This message reports an event, not an error
Severity
info
Facility
LOG_AUTH
UI_NETCONF_ERROR
System Log Message
NETCONF error: error-message
Description
The management process (mgd) normally sends error messages to the NETCONF client in the <rpc-error> tag element. It could not send that tag element, and instead sent the indicated error message in an XML comment.
Type
Error: An error occurred
Severity
warning
Facility
ANY
UI_PARSE_JUNOSCRIPT_ATTRIBUTES
System Log Message
Error parsing attributes in client junoscript tag
Description
The management process (mgd) encountered an error and exited while attempting to parse the XML attributes in the <junoscript> tag submitted by a client application.
Type
Error: An error occurred
Severity
error
Facility
LOG_AUTH
UI_READ_FAILED
System Log Message
read failed for peer peer-name: error-message
Description
The management process (mgd) uses the read() system call to access data sent by other JUNOS processes running on the routing platform (referred to as its peers). The system call failed for the indicated process.
Type
Error: An error occurred
Severity
error
Facility
ANY
Cause
An internal software failure occurred.
Action
Contact your technical support representative.
UI_READ_TIMEOUT
System Log Message
Timeout on read of peer 'peer-name'
Description
When communicating with other JUNOS processes running on the routing platform (referred to as peers), the management process (mgd) waits only a defined period for responses to arrive. The timeout period passed for the indicated process.
Type
Event: This message reports an event, not an error
Severity
notice
Facility
ANY
UI_REBOOT_EVENT
System Log Message
System halt-reboot by 'username'
Description
The indicated software process restarted as requested by the indicated user.
Type
Event: This message reports an event, not an error
Severity
warning
Facility
LOG_AUTH
UI_RESCUE_OPERATION
System Log Message
Committing rescue configuration because CONFIG button was pressed
Description
The management process (mgd) began a commit operation to activate the rescue configuration, because the CONFIG button on the chassis was pressed.
Type
Event: This message reports an event, not an error
Severity
notice
Facility
LOG_AUTH
UI_RESTART_EVENT
System Log Message
User 'username' restarting daemon 'process-name'description
Description
The indicated software process restarted as requested by the indicated user.
Type
Event: This message reports an event, not an error
Severity
warning
Facility
LOG_AUTH
UI_SCHEMA_CHECKOUT_FAILED
System Log Message
Schema is out of date and needs to be rebuilt
Description
The JUNOS user interface schema file records all CLI commands and configuration statements available in the JUNOS software. While initializing, the new management process (mgd) determined that the schema's sequence number means that the schema is incompatible with the JUNOS software installed on the routing platform.
Type
Error: An error occurred
Severity
alert
Facility
ANY
Cause
The schema is out of date.
Action
None; mgd will rebuild the schema based on the current JUNOS version.
UI_SCHEMA_MISMATCH_MAJOR
System Log Message
Schema major version mismatch for package package-name (expected-value vs. received-value)
Description
The JUNOS user interface schema file records all CLI commands and configuration statements available in the JUNOS software. While initializing, the management process (mgd) discovered that the major part (for example, '5' in '5.x') of the schema version number does not match the major version number of the JUNOS software installed on the routing platform. The mismatch could lead to corruption of the configuration database.
Type
Error: An error occurred
Severity
error
Facility
ANY
Cause
The schema is incompatible with the installed JUNOS software.
Action
None; mgd will rebuild the schema based on the current JUNOS version.
Cause
An internal software failure occurred.
Action
Contact your technical support representative.
UI_SCHEMA_MISMATCH_SEQUENCE
System Log Message
Schema header sequence numbers mismatch for package package-name
Description
The JUNOS user interface schema file records all CLI commands and configuration statements available in the JUNOS software. Schema sequence numbers serve as a checksum of the configuration data schema and ensure that the software used to access the database understands the data. The value in the database file did not match the expected value.
Type
Error: An error occurred
Severity
error
Facility
ANY
Cause
The JUNOS software installation did not succeed, possibly because of an internal software error.
Action
Contact your technical support representative.
UI_SCHEMA_SEQUENCE_ERROR
System Log Message
Schema sequence number mismatch
Description
The JUNOS user interface schema file records all CLI commands and configuration statements available in the JUNOS software. The management process (mgd) rebuilds the schema as necessary to be compatible with the JUNOS software installed on the routing platform. A sequence number in the schema acts as a checksum that represents its content and format. A JUNOS process attempted to access the schema but determined that the schema's sequence number means that it is incompatible with the process.
Type
Error: An error occurred
Severity
alert
Facility
ANY
Cause
An internal software failure occurred.
Action
Contact your technical support representative.
UI_TACPLUS_ERROR
System Log Message
TACACS+ failure: error-message
Description
The management process (mgd) failed to send a record to TACACS+.
Type
Error: An error occurred
Severity
notice
Facility
LOG_AUTH
UI_VERSION_FAILED
System Log Message
Unable to fetch system version: error-message
Description
The management process (mgd) could not retrieve version information from the kernel.
Type
Error: An error occurred
Severity
error
Facility
ANY
Action
Contact your technical support representative.
UI_WRITE_RECONNECT
System Log Message
Re-establishing connection to peer 'peer-name'
Description
The management process (mgd) reconnected to the indicated JUNOS process running on the routing platform.
Type
Event: This message reports an event, not an error
Severity
notice
Facility
ANY
Hide Navigation Pane
Show Navigation Pane
Download
SHA1