PFE System Log Messages
This chapter describes messages with the PFE prefix. They are generated by the Packet Forwarding Engine controller, which manages packet forwarding functions.
PFE_ANALYZER_CFG_FAILED
System Log Message
Error in Analyzer error-message for index = index error-code = error-code
Description
The configuration analyzer terminated because an error occured during the configuration.
Type
Error: An error occurred
Severity
error
Facility
ANY
PFE_ANALYZER_SHIM_CFG_FAILED
System Log Message
Error in Analyzer error-message for index = index error-code = error-code
Description
The configuration analyzer terminated because an error occured while the chip was being programmed.
Type
Error: An error occurred
Severity
error
Facility
ANY
PFE_ANALYZER_TABLE_WRITE_FAILED
System Log Message
index Could not create analyzer error-message table
Description
The logical interfaces (ifl) index failed to configure the analyzer because of an error.
Type
Error: An error occurred
Severity
error
Facility
ANY
PFE_ANALYZER_TASK_FAILED
System Log Message
Following task failed : error-message
Description
The task analyzer terminated because an error occurred during the task.
Type
Error: An error occurred
Severity
error
Facility
ANY
PFE_CBF_UNSUPPORTED
System Log Message
Internet Processor I does not support CoS-based forwarding
Description
The Internet Processor I application-specific integrated circuit (ASIC) does not support class-of-service (CoS)-based forwarding (CBF).
Type
Event: This message reports an event, not an error
Severity
warning
Facility
ANY
PFE_COS_B2_ONE_CLASS
System Log Message
COSMAN: classifier classifier-id-new for ifl index replaces classifer classifier-id-old still used
Description
Only one classifier can be active on a B2-based FPC at any given time.
Type
Error: An error occurred
Severity
error
Facility
ANY
PFE_COS_B2_UNSUPPORTED
System Log Message
COSMAN: B2 FPC cannot support classifier type classifier-type-name
Description
B2-based FPCs can only handle IP precedence classifiers. They do not support any other classifier.
Type
Error: An error occurred
Severity
error
Facility
ANY
PFE_FW_DELETE_MISMATCH_ERR
System Log Message
Instance mismatch for type (installed-firewall-name != deleted-firewall-name) ifl logical-interface-index family protocol-family
Description
Before a firewall is deleted, it is sanity checked against what is installed in the forwarding topology. A mismatch was detected between the firewall to be deleted and the forwarding topology, and the delete operation was canceled.
Type
Error: An error occurred
Severity
error
Facility
LOG_PFE
PFE_FW_IF_DIALER_ERR
System Log Message
DFW: output type (firewall-name) on ifl logical-interface-index rejected, invalid interface
Description
Firewalls that use the ipsec-sa action to forward traffic to an IP Security (IPSec) security association (SA) cannot be configured on the ES Physical Interface Card (PIC) that services the SA. That configuration creates traffic loops within the router and was probably unintended. The problematic filter was automatically removed from the indicated interface.
Type
Error: An error occurred
Severity
error
Facility
LOG_PFE
PFE_FW_IF_INPUT_ERR
System Log Message
DFW: input type (firewall-name) on ifl logical-interface-index rejected, invalid interface
Description
Firewalls that use the ipsec-sa action to forward traffic to an IP Security (IPSec) security association (SA) cannot be configured on the ES Physical Interface Card (PIC) that services the SA. That configuration creates traffic loops within the router and was probably unintended. The problematic firewall was automatically removed from the indicated interface.
Type
Error: An error occurred
Severity
error
Facility
LOG_PFE
PFE_FW_IF_OUTPUT_ERR
System Log Message
DFW: output type (firewall-name) on ifl logical-interface-index rejected, invalid interface
Description
Firewalls that use the ipsec-sa action to forward traffic to an IP Security (IPSec) security association (SA) cannot be configured on the ES Physical Interface Card (PIC) that services the SA. That configuration creates traffic loops within the router and was probably unintended. The problematic firewall was automatically removed from the indicated interface.
Type
Error: An error occurred
Severity
error
Facility
LOG_PFE
PFE_FW_PSF_DELETE_MISMATCH_ERR
System Log Message
Instance mismatch for type (installed-firewall-name != deleted-firewall-name) hardware label index family protocol-family
Description
Before a postservice firewall is deleted, it is sanity checked against what is installed in the forwarding topology. A mismatch was detected between the firewall to be deleted and the forwarding topology, and the delete operation was canceled.
Type
Error: An error occurred
Severity
error
Facility
LOG_PFE
PFE_FW_SYSLOG_ETH
System Log Message
FW: interface-name action destination-address source-address protocol-name (count packets)
Description
An Ethernet frame matched against a stateless firewall filter with the indicated 'syslog' action (A = Accept, D = Discard, R = Reject).
Type
Event: This message reports an event, not an error
Severity
info
Facility
ANY
PFE_FW_SYSLOG_IP
System Log Message
FW: interface-name action protocol-name source-address destination-address source-port-or-type destination-port-or-code (count packets)
Description
An IP packet matched against a stateless firewall filter with the indicated 'syslog' action (A = Accept, D = Discard, R = Reject).
Type
Event: This message reports an event, not an error
Severity
info
Facility
ANY
PFE_FW_SYSLOG_IP6_GEN
System Log Message
FW: interface-name action protocol-name source-address destination-address (count packets)
Description
An IP version 6 (IPv6) packet matched against a stateless firewall filter with the indicated 'syslog' action (A = Accept, D = Discard, R = Reject).
Type
Event: This message reports an event, not an error
Severity
info
Facility
ANY
PFE_FW_SYSLOG_IP6_ICMP
System Log Message
FW: interface-name action protocol-name source-address destination-address type type code error-code (count packets)
Description
An IP version 6 (IPv6) Internet Control Message Protocol (ICMP) packet matched against a stateless firewall filter with the indicated 'syslog' action (A = Accept, D = Discard, R = Reject).
Type
Event: This message reports an event, not an error
Severity
info
Facility
ANY
PFE_FW_SYSLOG_IP6_TCP_UDP
System Log Message
FW: interface-name action protocol-name source-address destination-address sport:source-port dport:destination-port (count packets)
Description
An IP version 6 (IPv6) Transmission Control Protocol/User Datagram Protocol (TCP/UDP) packet matched against a stateless firewall filter with the indicated 'syslog' action (A = Accept, D = Discard, R = Reject).
Type
Event: This message reports an event, not an error
Severity
info
Facility
ANY
PFE_MGCP_MEM_INIT_FAILED
System Log Message
Failed to create memory pool for error-message
Description
Failed to initialize the MGCP memory pool.
Type
Error: An error occurred
Severity
error
Facility
LOG_PFE
PFE_MGCP_REG_HDL_FAIL
System Log Message
Failed to register object-name handle
Description
Failed to register the handler with the external module.
Type
Error: An error occurred
Severity
error
Facility
LOG_PFE
PFE_NH_RESOLVE_THROTTLED
System Log Message
Next-hop resolution requests from interface logical-interface-index throttled
Description
The Packet Forwarding Engine throttled next-hop resolution requests from the indicated interface, because the high number of requests might constitute an attempted denial-of-service (DoS) attack. Examples of events that generate next-hop resolution requests include an attempt to forward a packet without an Address Resolution Protocol (ARP) entry and receiving a multicast data packet with no matching route. Normally, the Packet Forwarding Engine forwards the requests to the Routing Engine.
Type
Event: This message reports an event, not an error
Severity
info
Facility
LOG_PFE
PFE_SCCP_ADD_PORT_FAIL
System Log Message
Failed to add SCCP ALG port to application definition table
Description
Failed to add the SCCP port to the application definition table.
Type
Error: An error occurred
Severity
error
Facility
LOG_PFE
PFE_SCCP_DEL_PORT_FAIL
System Log Message
Failed to remove SCCP ALG port from application definition table
Description
Failed to delete the SCCP port from application definition table.
Type
Error: An error occurred
Severity
error
Facility
LOG_PFE
PFE_SCCP_REG_NAT_VEC_FAIL
System Log Message
Failed to add SCCP ALG vector to flow module
Description
Failed to register the SCCP vector with the flow module.
Type
Error: An error occurred
Severity
error
Facility
LOG_PFE
PFE_SCCP_REG_RM_FAIL
System Log Message
Failed to register SCCP client to Resource Manager
Description
Failed to register the SCCP Resource Manager client.
Type
Error: An error occurred
Severity
error
Facility
LOG_PFE
PFE_SCCP_REG_VSIP_FAIL
System Log Message
Failed to register SCCP client to VoIP State IP port
Description
Failed to register the SCCP client to VoIP State IP port.
Type
Error: An error occurred
Severity
error
Facility
LOG_PFE
PFE_SCCP_RM_CLIENTID_FAIL
System Log Message
Failed to get SCCP Resource Manager client identifier
Description
Failed to get the SCCP Resource Manager client identifier.
Type
Error: An error occurred
Severity
error
Facility
LOG_PFE
PFE_SCREEN_MT_CFG_ERROR
System Log Message
failed to operation the screen config due to error-message
Description
failed to change the configuration of screen module
Type
Error: An error occurred
Severity
error
Facility
LOG_PFE
PFE_SCREEN_MT_CFG_EVENT
System Log Message
[operation]: screen name - context-name
Description
configuration of screen module is changed
Type
Event: This message reports an event, not an error
Severity
info
Facility
LOG_PFE
PFE_SFLOW_CONFIGURATION_FAILED
System Log Message
sflow configuration on hardware failed for ifl index = index
Description
The sflow configuration for the ifl index could not be programmed in the hardware
Type
Error: An error occurred
Severity
error
Facility
ANY
PFE_SFLOW_HARDWARE_CFG_FAILED
System Log Message
dev = device-id, port = destination-port, hardware error-code = error-code
Description
The sflow configuration for the port could not be programmed in the hardware
Type
Error: An error occurred
Severity
error
Facility
ANY
PFE_SIP_ADD_PORT_FAIL
System Log Message
Failed to add SIP ALG port to application definition table
Description
Failed to add the SIP port to the application definition table.
Type
Error: An error occurred
Severity
error
Facility
LOG_PFE
PFE_SIP_DEL_PORT_FAIL
System Log Message
Failed to delete SIP ALG port from application definition table
Description
Failed to remove the SIP port from the application definition table.
Type
Error: An error occurred
Severity
error
Facility
LOG_PFE
PFE_SIP_MEM_INIT_FAILED
System Log Message
Failed to create memory pool for object-name
Description
Failed to create a memory pool for SIP.
Type
Error: An error occurred
Severity
error
Facility
LOG_PFE
PFE_SIP_REG_HDL_FAIL
System Log Message
Failed to register object-name handle
Description
Failed to register the handler with the external module.
Type
Error: An error occurred
Severity
error
Facility
LOG_PFE