LIBMSPRPC System Log Messages
This chapter describes messages with the LIBMSPRPC prefix. They are generated by the mspinfo process, which is responsible for RPC communication between the Routing Engine (RE) and the Multiservices PICs.
LIBMSPRPC_CLIENT_INIT_FAILED
System Log Message
Can't create msprpc client: error-message
Description
A JUNOS process (mspinfo) could not establish initialization of the RPC client.
Type
Error: An error occurred
Severity
error
Facility
ANY
Cause
Possible reasons: process is out of memory
Action
Contact your technical support representative.
LIBMSPRPC_CLIENT_KCOM_FAILED
System Log Message
Can't initialize kcom for msprpc client: error-message
Description
A JUNOS process (mspinfo) could not establish initialization of the kcom subsystem.
Type
Error: An error occurred
Severity
error
Facility
ANY
Cause
Possible reasons: can't initialize kcom services.
Action
Contact your technical support representative.
LIBMSPRPC_CLIENT_KCOM_NO_IF
System Log Message
No active extension-provider interfaces
Description
A JUNOS process (mspinfo) could not found any configured and active extension-provider interfaces.
Type
Error: An error occurred
Severity
notice
Facility
ANY
Cause
Possible reasons: can't initialize kcom services.
Action
Contact your technical support representative.
LIBMSPRPC_CLIENT_NO_CONNECTION
System Log Message
Failed connecting fpc=fpc-slot, pic=pic-slot
Description
Remote execution of the command given from the RE to the PIC failed, can not connect to the PIC.
Type
Error: An error occurred
Severity
notice
Facility
ANY
Cause
Possible reasons: a)PIC appears online but is not responding b)msprpc server is not running on the PIC.
Action
Contact your technical support representative.
LIBMSPRPC_CLIENT_NO_REPLY
System Log Message
Error executing "command": no reply from the PIC
Description
Remote execution of the command given from the RE to the PIC failed, no reply from the PIC.
Type
Error: An error occurred
Severity
notice
Facility
ANY
Cause
Possible reasons: a)wrong command b)insufficient permissions c)wrong arguments d)PIC appears online but is not responding e)msprpc server is not running on the PIC.
Action
Contact your technical support representative.
LIBMSPRPC_CLIENT_PIC_DOWN
System Log Message
Interface interface-name is down
Description
Remote execution of the command given from the RE to the PIC failed, the PIC is down.
Type
Error: An error occurred
Severity
error
Facility
ANY
Cause
Possible reasons: the given PIC is not responding and/or is offline.
Action
Contact your technical support representative.
LIBMSPRPC_CLIENT_WRONG_OUTPUT
System Log Message
Error executing "command": output length exceeds correct-length characters
Description
Remote execution of the command given from the RE to the PIC failed, PIC returned unexpected output.
Type
Error: An error occurred
Severity
notice
Facility
ANY
Cause
Possible reasons: a)wrong command b)wrong arguments.
Action
Contact your technical support representative.