This chapter describes messages with the JSRPD prefix. They are generated by the Juniper Services Redundancy Protocol (jsrpd) process, which controls chassis clustering.

JSRPD_DAEMONIZE_FAILED

System Log Message

Aborting, unable to run in the background as a daemon: error-message

Description

The Juniper Services Redundancy Protocol process (JSRPD) failed to create a version of itself to run in the background.

Type

Error: An error occurred

Severity

emergency

Facility

LOG_DAEMON

JSRPD_DUPLICATE

System Log Message

Another copy of this program is running

Description

The Juniper Services Redundancy Protocol process (JSRPD) detected that another version of itself is already running.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

JSRPD_NODE_STATE_CHANGE

System Log Message

Nodechassis-id state due to reason

Description

The Juniper Services Redundancy Protocol process (JSRPD) detected an event, such as failover, that caused the state of the chassis cluster node to change due to the reason indicated in the log.

Type

Event: This message reports an event, not an error

Severity

error

Facility

LOG_DAEMON

Cause

A link failure occurred and the secondary node is disabled.

Cause

The secondary node has recovered from link failure and is being rebooted to recover from the disabled state.

Action

Contact your technical support representative.

JSRPD_NOT_ROOT

System Log Message

Must be run as root

Description

The Juniper Services Redundancy Protocol process (JSRPD) can be instantiated only by the user with root privileges.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

JSRPD_PID_FILE_LOCK

System Log Message

Unable to lock PID file: error-message

Description

The Juniper Services Redundancy Protocol process (JSRPD) failed to lock the PID file, which serves to prevent multiple instances of the process from running simultaneously.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

JSRPD_PID_FILE_UPDATE

System Log Message

Unable to update process PID file: error-message

Description

The Juniper Services Redundancy Protocol process (JSRPD) failed to update the PID file, which serves to prevent multiple instances of the process from running simultaneously.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

JSRPD_REDUNDANCY_MODE_CHANGE

System Log Message

Redundancy mode change will not be effective until all nodes in the cluster are rebooted simultaneously

Description

The Juniper Services Redundancy Protocol process (JSRPD) detected a change in chassis cluster redundancy mode. The new mode is not effective until all nodes in the cluster are rebooted.

Type

Error: An error occurred

Severity

warning

Facility

LOG_DAEMON

JSRPD_REDUNDANCY_MODE_MISMATCH

System Log Message

Change in HA redundancy mode detected..please reboot all nodes in the cluster simultaneously!!

Description

The Juniper Services Redundancy Protocol process (JSRPD) detected a change in the chassis cluster redundancy mode configuration and detected that only some (not all) of the nodes rebooted. The new mode is not effective until all nodes in the cluster are rebooted.

Type

Error: An error occurred

Severity

warning

Facility

LOG_DAEMON

JSRPD_RG_STATE_CHANGE

System Log Message

Redundancy-group rg-id transitioned from 'old-state' to 'new-state' state due to reason

Description

The Juniper Services Redundancy Protocol process (JSRPD) detected an event that caused the state of the chassis cluster redundancy group to change due to the reason indicated in the log.

Type

Event: This message reports an event, not an error

Severity

alert

Facility

LOG_DAEMON

JSRPD_SET_CS_MON_FAILURE

System Log Message

Cold-sync Monitor failed for redundancy-group rg-id

Description

The Juniper Services Redundancy Protocol process (JSRPD) detected cold-sync monitoring failure for a redundancy group.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

JSRPD_SET_INTF_MON_FAILURE

System Log Message

Interface Monitor failed for redundancy-group rg-id

Description

The Juniper Services Redundancy Protocol process (JSRPD) detected interface monitoring failure for a redundancy group.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

JSRPD_SET_IP_MON_FAILURE

System Log Message

IP Monitor failed for redundancy-group rg-id

Description

The Juniper Services Redundancy Protocol process (JSRPD) detected IP address monitoring failure for a redundancy group.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

JSRPD_SET_NPC_MON_FAILURE

System Log Message

NPC Monitor failed for redundancy-group rg-id

Description

The Juniper Services Redundancy Protocol process (JSRPD) detected Network Processing Card (NPC) monitoring failure for a redundancy group.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

JSRPD_SET_OTHER_INTF_MON_FAIL

System Log Message

Interface Monitor failed on other node for redundancy-group rg-id

Description

The Juniper Services Redundancy Protocol process (JSRPD) detected interface monitoring failure on the other node for a redundancy group.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

JSRPD_SET_SPU_MON_FAILURE

System Log Message

SPU Monitor failed for redundancy-group rg-id

Description

The Juniper Services Redundancy Protocol process (JSRPD) detected Services Processing Unit (SPU) monitoring failure for a redundancy group.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

JSRPD_SOCKET_CREATION_FAILURE

System Log Message

Socket creation (server) failed unexpectedly error-message.

Description

The Juniper Services Redundancy Protocol process (JSRPD) failed to create a socket.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

JSRPD_SOCKET_LISTEN_FAILURE

System Log Message

Socket listen (server) failed unexpectedly. error-message

Description

The Juniper Services Redundancy Protocol process (JSRPD) failed to listen on a socket.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

JSRPD_SOCKET_RECV_HB_FAILURE

System Log Message

Socket reception of heartbeat from failed unexpectedly error-message.

Description

The Juniper Services Redundancy Protocol process (JSRPD) failed to receive heartbeat.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

JSRPD_UNSET_CS_MON_FAILURE

System Log Message

Cold-sync Monitor failure recovered for redundancy-group rg-id

Description

The Juniper Services Redundancy Protocol process (JSRPD) detected that the previous cold-sync monitoring failure no longer exists for a redundancy group.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

JSRPD_UNSET_INTF_MON_FAILURE

System Log Message

Interface Monitor failure recovered for redundancy-group rg-id

Description

The Juniper Services Redundancy Protocol process (JSRPD) detected that the previous interface monitoring failure no longer exists for a redundancy group.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

JSRPD_UNSET_IP_MON_FAILURE

System Log Message

IP Monitor failure recovered for redundancy-group rg-id

Description

The Juniper Services Redundancy Protocol process (JSRPD) detected that the previous IP address monitoring failure no longer exists for a redundancy group.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

JSRPD_UNSET_NPC_MON_FAILURE

System Log Message

NPC Monitor failure recovered for redundancy-group rg-id

Description

The Juniper Services Redundancy Protocol process (JSRPD) detected that the previous Network Processing Card (NPC) monitoring failure no longer exists for a redundancy group.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

JSRPD_UNSET_OTHER_INTF_MON_FAIL

System Log Message

Interface Monitor failure recovered on other node for redundancy-group rg-id

Description

The Juniper Services Redundancy Protocol process (JSRPD)\ detected that the previous interface monitoring failure on the other node no longer exists for a redundancy group.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

JSRPD_UNSET_SPU_MON_FAILURE

System Log Message

SPU Monitor failure recovered for redundancy-group rg-id

Description

The Juniper Services Redundancy Protocol process (JSRPD) detected that the previous Services Processing Unit (SPU) monitoring failure no longer exists for a redundancy group.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

JSRPD_USAGE

System Log Message

Usage: jsrpd [-C] [-N] [-X] [-d debug-level] [-l] [-v]

Description

The Juniper Services Redundancy Protocol process (JSRPD) was invoked with incorrect options.

Type

Event: This message reports an event, not an error

Severity

error

Facility

LOG_DAEMON