JPTSPD System Log Messages
This chapter describes messages with the JPTSPD prefix. They are generated by the packet-triggered subscriber process (jptspd) which creates and manages packet-triggered subscriber interfaces. A packet-triggered subscriber interface is created when the router receives a packet with an IP source address that does not match any entries in the demultiplexer table. When the router detects an unmatched packet, it generates a trigger event that determines whether to create a dynamic subscriber interface or configure an existing interface.
JPTSPD_INIT_FAILURE
System Log Message
JPTSPD failed to initialize
Description
The packet triggered subscriber process (jptspd) initialization failed.
Type
Error: An error occurred
Severity
error
Facility
ANY
Cause
One possible cause is that the system is out of memory.
Action
Contact your technical support representative.
JPTSPD_OUT_OF_MEMORY
System Log Message
Out of memory
Description
The packet triggered subscriber process (jptspd) could not dynamically allocate memory.
Type
Error: An error occurred
Severity
error
Facility
ANY
Cause
A software bug caused a memory leak, or too many subscriber and service sessions.
Action
Contact your technical support representative.
JPTSPD_PIC_CONNECTED
System Log Message
JPTSPD connected to pic pic-name
Description
The packet triggered subscriber process (jptspd) connected to a PIC.
Type
Event: This message reports an event, not an error
Severity
info
Facility
ANY
JPTSPD_PIC_DISCONNECTED
System Log Message
JPTSPD disconnected to pic pic-name reason
Description
The packet triggered subscriber process (jptspd) disconnected to a PIC.
Type
Event: This message reports an event, not an error
Severity
info
Facility
ANY
JPTSPD_SRC_FAST_SYNC_ABORT
System Log Message
JPTSPD fast synchronization was aborted partition-name
Description
The packet triggered subscriber process (jptspd) aborted fast synchronization with SRC.
Type
Event: This message reports an event, not an error
Severity
info
Facility
ANY
Cause
One possible cause is that the connection between jptspd and SRC is down.
JPTSPD_SRC_FAST_SYNC_DONE
System Log Message
JPTSPD fast synchronization was done partition-name
Description
The packet triggered subscriber process (jptspd) finished fast synchronization with SRC.
Type
Event: This message reports an event, not an error
Severity
info
Facility
ANY
JPTSPD_SRC_FAST_SYNC_START
System Log Message
JPTSPD fast synchronization started partition-name
Description
The packet triggered subscriber process (jptspd) started fast synchronization with SRC.
Type
Event: This message reports an event, not an error
Severity
info
Facility
ANY
JPTSPD_SRC_FULL_SYNC_ABORT
System Log Message
JPTSPD full synchronization was aborted partition-name
Description
The packet triggered subscriber process (jptspd) aborted full synchronization with SRC.
Type
Event: This message reports an event, not an error
Severity
info
Facility
ANY
Cause
One possible cause is that the connection between jptspd and SRC is down.
JPTSPD_SRC_FULL_SYNC_DONE
System Log Message
JPTSPD full synchronization was done partition-name
Description
The packet triggered subscriber process (jptspd) finished full synchronization with SRC.
Type
Event: This message reports an event, not an error
Severity
info
Facility
ANY
JPTSPD_SRC_FULL_SYNC_START
System Log Message
JPTSPD full synchronization started partition-name
Description
The packet triggered subscriber process (jptspd) started full synchronization with SRC.
Type
Event: This message reports an event, not an error
Severity
info
Facility
ANY