JCS System Log Messages
This chapter describes messages with the JCS prefix. They are generated by the Juniper Control System (jcsd) process which provides the user interface to the control processes for the management modules and switch modules in the JCS 1200 platform.
JCS_BBD_LOAD_FAILURE
System Log Message
Blade slot load BBD falure: error-message
Description
The JCS process (jcsd) could not load blade bay data for the specified blade.
Type
Error: An error occurred
Severity
error
Facility
LOG_DAEMON
JCS_BBD_LOCAL_MISMATCH
System Log Message
Blade slot BBD error-message mismatch (expected-value != received-value)
Description
The blade bay data retrieved for the specified blade does not match the data loaded during the reboot process. This error usually indicates that blade bay data in the JCS Management Module was changed since the last reboot.
Type
Error: An error occurred
Severity
error
Facility
LOG_DAEMON
JCS_BBD_NOT_FOUND
System Log Message
Blade slot bay data not found
Description
Blade bay data was not found for the specified blade.
Type
Error: An error occurred
Severity
error
Facility
LOG_DAEMON
JCS_BBD_NOT_VALID
System Log Message
Blade slot BBD is invalid
Description
The blade bay data for the specified blade is invalid.
Type
Error: An error occurred
Severity
error
Facility
LOG_DAEMON
JCS_BBD_PARSE_ERROR
System Log Message
Blade slot bay data parse error - error-message
Description
The blade bay data for the specified blade did not parse correctly.
Type
Error: An error occurred
Severity
error
Facility
LOG_DAEMON
JCS_BBD_PEER_MISMATCH
System Log Message
Peer blade slot BBD error-message mismatch (expected-value != received-value)
Description
The blade bay data retrieved for the specified peer blade does not match the data retrieved for the local blade. This error indicates that blade bay data in the JCS Management Module was not configured properly.
Type
Error: An error occurred
Severity
error
Facility
LOG_DAEMON
JCS_BBD_SYSTEM_CONFLICT
System Log Message
Local BBD error-message (value) conflicts with blade slot
Description
The blade bay data retrieved for the local blade conflicts with another blade in the JCS. This error indicates that blade bay data in the JCS Management Module was not configured properly.
Type
Error: An error occurred
Severity
error
Facility
LOG_DAEMON
JCS_EXT_LINK_STATE
System Log Message
Switch slot EXT link state is state
Description
The JCS process (jcsd) detects a change of state for the external link of the indicated switch module.
Type
Event: This message reports an event, not an error
Severity
info
Facility
LOG_DAEMON
JCS_INVALID_BANDWIDTH_ERROR
System Log Message
Invalid bandwidth percent (value)
Description
The specified switch bandwidth is invalid. The bandwidth is defined as a percentage between 1 and 100.
Type
Error: An error occurred
Severity
error
Facility
LOG_DAEMON
JCS_KERNEL_RSD_LINK_DOWN
System Log Message
Kernel RSD link is DOWN (error-message)
Description
The JCS process (jcsd) has disabled kernel RSD communcation for the specified reason.
Type
Error: An error occurred
Severity
error
Facility
LOG_DAEMON
JCS_KERNEL_RSD_LINK_ENABLED
System Log Message
Kernel RSD link is ENABLED (error-message)
Description
The JCS process (jcsd) has verified the blade bay data and enabled kernel RSD communication.
Type
Event: This message reports an event, not an error
Severity
info
Facility
LOG_DAEMON
JCS_MM_COMMUNICATION_ERROR
System Log Message
MM communication error (error-message)
Description
The JCS process (jcsd) could not send an SNMP request to the Management Module because of the indicated error.
Type
Error: An error occurred
Severity
error
Facility
LOG_DAEMON
JCS_MM_COMMUNICATION_OK
System Log Message
MM communication is OK
Description
The JCS process (jcsd) has established a communication link with the Management Module.
Type
Event: This message reports an event, not an error
Severity
info
Facility
LOG_DAEMON
JCS_PEER_BLADE_STATE
System Log Message
Peer blade slot is state
Description
The JCS process (jcsd) detects a change of state for the indicated blade.
Type
Event: This message reports an event, not an error
Severity
info
Facility
LOG_DAEMON
JCS_READ_BANDWIDTH_ERROR
System Log Message
Read bandwidth error (error-code)
Description
The indicated error occured when attempting to read the current switch bandwidth.
Type
Error: An error occurred
Severity
error
Facility
LOG_DAEMON
JCS_READ_BBD_ERROR
System Log Message
Read blade bay data (error=error-code)
Description
The indicated error occured when attempting to read the current blade bay data via a sysctl call.
Type
Error: An error occurred
Severity
error
Facility
LOG_DAEMON
JCS_RSD_LINK_STATE
System Log Message
Switch slot RSD link state is state
Description
The JCS process (jcsd) detects a change of state for the RSD link of the indicated switch module.
Type
Event: This message reports an event, not an error
Severity
info
Facility
LOG_DAEMON
JCS_SWITCH_BANDWIDTH_CONFIG
System Log Message
Switch slot bandwidth value1 percent (value2 KBPS)
Description
The indicated JCS Switch Module has changed the bandwidth configuration to the specified value.
Type
Event: This message reports an event, not an error
Severity
info
Facility
LOG_DAEMON
JCS_SWITCH_COMMUNICATION_ERROR
System Log Message
Switch slot communication error (error-message)
Description
The JCS process (jcsd) could not send an SNMP request to the indicated Switch Module because of the indicated error.
Type
Error: An error occurred
Severity
error
Facility
LOG_DAEMON
JCS_SWITCH_COMMUNICATION_OK
System Log Message
Switch slot communication is OK
Description
The JCS process (jcsd) has established a communication link with the indicated Switch Module.
Type
Event: This message reports an event, not an error
Severity
info
Facility
LOG_DAEMON
Hide Navigation Pane
Show Navigation Pane
Download
SHA1